2013
DOI: 10.1016/j.icheatmasstransfer.2013.05.012
|View full text |Cite
|
Sign up to set email alerts
|

Heat transfer and friction factor characteristics in turbulent flow through a tube fitted with perforated twisted tape inserts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
38
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 200 publications
(40 citation statements)
references
References 30 publications
1
38
1
Order By: Relevance
“…3(a) and (b) show the comparison of Nusselt number and friction factor of the plain tube obtain from the simulation results with those from the proposed correlations. The data from the simulation are in agreement with Dittus-Boelter's Nusselt number and Blasius's friction factor correlations [9] with the discrepancy of less than 1.97%, 1.55%, respectively. The heat transfer rate of twist-tapes type 1 and 2 insert in terms of Nusselt number is shown in Fig.…”
Section: Resultssupporting
confidence: 78%
See 1 more Smart Citation
“…3(a) and (b) show the comparison of Nusselt number and friction factor of the plain tube obtain from the simulation results with those from the proposed correlations. The data from the simulation are in agreement with Dittus-Boelter's Nusselt number and Blasius's friction factor correlations [9] with the discrepancy of less than 1.97%, 1.55%, respectively. The heat transfer rate of twist-tapes type 1 and 2 insert in terms of Nusselt number is shown in Fig.…”
Section: Resultssupporting
confidence: 78%
“…In order to appraise the heat transfer augmentation performance of the two different perforated twist-tapes insert with plain tube [9]. Heat transfer enhancement efficiency calculated using Eq.…”
Section: Resultsmentioning
confidence: 99%
“…The results demonstrated that using CuO nanofluid with twisted alternate axis (TA) obtain a higher Nusselt number and thermal performance, and the twisted tape in alternate axis was about 89% more effective than typical twisted tape. Various types of twisted tape such as hollow, double, perforated, and dimpled configurations based on the physical properties, e.g., hollow widths and hole diameters, were investigated in many studies [17][18][19][20][21]. Li et al [22] carried out a numerical study on her transfer enhancement in a tube with centrally hollow narrow twisted tape under laminar flow conditions.…”
Section: Twisted Tape Insertsmentioning
confidence: 99%
“…Outlet was specified as pressure outlet, which fixes static pressure as 1.013x10 4 Pa. Outer surface of storage system was insulated to reduce heat loss from storage system was set as zero heat flux.…”
Section: Boundary Conditionmentioning
confidence: 99%