2009
DOI: 10.1016/j.ijheatmasstransfer.2009.05.032
|View full text |Cite
|
Sign up to set email alerts
|

Heat transfer and friction characteristics of solar air heater ducts having integral inclined discrete ribs on absorber plate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
36
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 156 publications
(42 citation statements)
references
References 14 publications
2
36
0
Order By: Relevance
“…Taslim et al (1996) observed that, heat transfer from the heated surfaces roughened with V-down ribs is low near the trailing ends, due to heating up of the air as it moves along the ribs from leading to trailing ends. Aharwal et al (2009) (2011) also concluded that introduction of a gap near the trailing end of the inclined and Vshaped ribs respectively, enhances the rate of heat transfer from the absorber plate of a solar air heater. As shown in the figure, fixing of a small staggered rib piece in front of each gap at a distance of 2/3 rd of the pitch, further improves the rate of heat transfer.…”
Section: Flow Patterns In Duct Roughened On One Broad Sidementioning
confidence: 99%
See 1 more Smart Citation
“…Taslim et al (1996) observed that, heat transfer from the heated surfaces roughened with V-down ribs is low near the trailing ends, due to heating up of the air as it moves along the ribs from leading to trailing ends. Aharwal et al (2009) (2011) also concluded that introduction of a gap near the trailing end of the inclined and Vshaped ribs respectively, enhances the rate of heat transfer from the absorber plate of a solar air heater. As shown in the figure, fixing of a small staggered rib piece in front of each gap at a distance of 2/3 rd of the pitch, further improves the rate of heat transfer.…”
Section: Flow Patterns In Duct Roughened On One Broad Sidementioning
confidence: 99%
“…transverse ribs (Gupta et al (1993)), inclined ribs (Gupta et al (1997)), V-shaped ribs (Momin et al (2002)), staggered discrete V-shaped ribs (Mulluwork (2000)), V-up and V-down discrete ribs (Karwa (2003)), inclined rib with gap (Aharwal et al (2009)), V-rib with gap (Singh et al (2011)) and multi V-rib with gaps (Anil et al (2013)) resulted in enhancement of the performance of solar air heaters. Patil et al (2012) experimented with a variation of the V-rib with one gap geometry by fixing a staggered rib piece in front of each gap and reported improvement in heat transfer and thermohydraulic performance.…”
Section: Introductionmentioning
confidence: 99%
“…Aharwal,Saini,Gandhi [7] done this experiment to to present the experimental investigation of heat transfer and friction factor characteristics of a rectangular duct roughened with repeated square cross-section split-rib with a gap, on one broad wall arranged at an inclination with respect to the flow direction. The duct has a width to height ratio (W/H) of 5.84, relative roughness pitch (P/e) of 10, relative roughness height (e/Dh) of 0.0377, and angle of attack (α) of 60˚.…”
Section: Gap In Inclined Continuous Ribmentioning
confidence: 99%
“…To reduce frictional losses investigator, introduce gaps with in the roughness geometries; viz. inclined rib with gap [(i.e., [11]) V-rib with gap [(i.e., [12]) and multi V-rib with gap [(i.e., [13]) With the help of gap added advantage of secondary flow through the gaps while moving along inclined ribs and through gaps fluid accelerated which erupting the growth of boundary layer and on the other hand friction factor encountered less then continuous ribs. Other than inclined and transverse ribs roughness arc shape roughness are also investigated to enhance the heat transfer and efficiency of solar air heater.…”
Section: Introductionmentioning
confidence: 99%