2020
DOI: 10.1109/tia.2020.3021060
|View full text |Cite
|
Sign up to set email alerts
|

Grid Synchronization of WEC-PV-BES Based Distributed Generation System Using Robust Control Strategy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(11 citation statements)
references
References 45 publications
0
11
0
Order By: Relevance
“…22 to Fig. 24 The experimental results of the transitions in the three-phase currents IGabc, Iiabc, ILabc are shown in Fig. 23(a), (b); where the load current remains stable during transitions.…”
Section: E Dynamic Transition From Gtt To Ogtmentioning
confidence: 99%
See 2 more Smart Citations
“…22 to Fig. 24 The experimental results of the transitions in the three-phase currents IGabc, Iiabc, ILabc are shown in Fig. 23(a), (b); where the load current remains stable during transitions.…”
Section: E Dynamic Transition From Gtt To Ogtmentioning
confidence: 99%
“…Therefore, the power quality improvement is a significant issue in GTT along with extracting maximum available PV power [16]. The literature [17][18][19][20][21][22][23][24] lists a broad range of methods of identification of harmonic components. The harmonics methods of detection are mainly used in the load current to isolate the fundamental component and harmonics.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Battery Energy Storage Systems (BESS) are a more viable option compared to other energy storage systems due to their technical as well as economical merits. A number of topologies and control schemes for hybrid systems have been proposed in the literature [1][2][3][4][5][6][7][8][9][10]. Among them, Omar [1] presented a performance analysis of a grid-connected PV-wind hybrid power system during variations of environmental as well as load conditions.…”
Section: Introductionmentioning
confidence: 99%
“…As a result, in addition to enhancing the stability robustness of VSIs, a limited bandwidth PLL is typically used, compromising the system's dynamic performance greatly. To circumvent the PLL system's limitations, some studies [23][24][25] proposed frequency locked loop (FLL)-based synchronization solution for the MG's VSI [23][24][25]. Power control approach based on PLL-less CCT is introduced in [26] for grid-tied hybrid MG's VSI.…”
Section: Introductionmentioning
confidence: 99%