2010
DOI: 10.1016/j.trac.2010.07.016
|View full text |Cite
|
Sign up to set email alerts
|

Green analytical chemistry in the determination of organic pollutants in the aquatic environment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
45
0
3

Year Published

2012
2012
2020
2020

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 125 publications
(48 citation statements)
references
References 130 publications
0
45
0
3
Order By: Relevance
“…An isocratic procedure was achieved using the vancomycin-based CSP (Chirobiotic TM V column) with 150 × 2.1 mm i.d., with a flow rate of 0.32 mL min −1 and the column oven set at 20 • C. Several attempts were performed to achieve the best condition for enantiomeric resolution, as varying the proportion of ethanol, the column oven temperature and the flow rate, in order to achieve enantioseparation for all target pharmaceuticals within the shortest elution time. The conditions established used ethanol as organic solvent as recommend by green chromatography method development directives [48]. The enantioseparation of sixteen enantiomers of multi-therapeutic classes using ethanol and ammonium acetate buffer with a low flow rate (0.32 mL min −1 ) was achieved in 30 minutes (Fig.…”
Section: Enantiomeric Resolutionmentioning
confidence: 99%
“…An isocratic procedure was achieved using the vancomycin-based CSP (Chirobiotic TM V column) with 150 × 2.1 mm i.d., with a flow rate of 0.32 mL min −1 and the column oven set at 20 • C. Several attempts were performed to achieve the best condition for enantiomeric resolution, as varying the proportion of ethanol, the column oven temperature and the flow rate, in order to achieve enantioseparation for all target pharmaceuticals within the shortest elution time. The conditions established used ethanol as organic solvent as recommend by green chromatography method development directives [48]. The enantioseparation of sixteen enantiomers of multi-therapeutic classes using ethanol and ammonium acetate buffer with a low flow rate (0.32 mL min −1 ) was achieved in 30 minutes (Fig.…”
Section: Enantiomeric Resolutionmentioning
confidence: 99%
“…; these products may be hazardous to human health and even for the environment. 15,16 From an economic point of view, GAC has also exerted a positive influence on reducing operating costs and the treatment of waste generated by analytical procedures. In addition, the use of environmentally friendly procedures is required for International Organization for Standardization (ISO) 14000 certification.…”
Section: −14mentioning
confidence: 99%
“…10,11 Os biossensores são definidos 12 como um subgrupo dos sensores químicos capazes de proporcionar informação analítica quantitativa ou semiquantitativa, usando um elemento de reconhecimento biológico (como enzimas, anticorpos, proteínas, tecidos, microorganismos) em contato a transdutores químicos ou físicos (como eletroquímicos, ópticos, térmicos, etc). Dentre as substâncias biológicas mais usadas, destacam-se as enzimas, que podem ser encontradas em sua forma purificada ou presentes em microorganismos ou em porções de tecido animal e vegetal.…”
Section: Introductionunclassified