2015
DOI: 10.1016/j.enzmictec.2015.06.006
|View full text |Cite
|
Sign up to set email alerts
|

Glucose biosensor based on glucose oxidase immobilized at gold nanoparticles decorated graphene-carbon nanotubes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
38
0
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 113 publications
(40 citation statements)
references
References 30 publications
1
38
0
1
Order By: Relevance
“…Numerous studies (Talbert et al, 2014;Wong et al, 2008;Choi et al, 2015;Singh and Verma, 2013;Röcker et al, 2016) have shown increase in the traditional uses of this enzyme. In addition, GOx has more recently been used in biosensor applications (Devasenathipathy et al, 2015;Turkmen et al, 2014;Hwa, 2015;Lin et al, 2015) and other nanotechnological applications have been demonstrated Liu et al, 2014;Sapountzi et al, 2017). In this context, the new Amazonian source of this enzyme (A. niger LMM01) and production of GOx in a semi-continuous process demonstrates the importance of the present work.…”
Section: Discussionmentioning
confidence: 91%
“…Numerous studies (Talbert et al, 2014;Wong et al, 2008;Choi et al, 2015;Singh and Verma, 2013;Röcker et al, 2016) have shown increase in the traditional uses of this enzyme. In addition, GOx has more recently been used in biosensor applications (Devasenathipathy et al, 2015;Turkmen et al, 2014;Hwa, 2015;Lin et al, 2015) and other nanotechnological applications have been demonstrated Liu et al, 2014;Sapountzi et al, 2017). In this context, the new Amazonian source of this enzyme (A. niger LMM01) and production of GOx in a semi-continuous process demonstrates the importance of the present work.…”
Section: Discussionmentioning
confidence: 91%
“…Our electrode shows sensitivity and LOD similar to results by Palanisamy et al 18 which used thick GO hybridized with MWCNT and supported by glassy carbon electrode (GCE) that demonstrated high thermodynamic surface adsorption 59 and specific thermodynamics adsorption and redox reduction mechanism with GOx. 60 Although our electrode underperformed those with thick RGO, 11,18,28,29,53 it demonstrated the feasibility of immobilizing GOx onto monolayer RGO for glucose sensors. The LOD of our electrodes outperformed those reported previously for GOx immobilized hybrids of AuNPs-RGO 56 and CdS-RGO 57 on GCE and RGO-IL on modified Au.…”
Section: Resultsmentioning
confidence: 99%
“…The sensitivity and LOD of the fabricated electrode are compared to various electrodes as shown in Table II. 11,18,28,29,[53][54][55][56][57][58] Most of the electrodes in the review have high sensitivity and good LOD as they used thick GO prepared by a modified Hummers method. Our electrode shows sensitivity and LOD similar to results by Palanisamy et al 18 which used thick GO hybridized with MWCNT and supported by glassy carbon electrode (GCE) that demonstrated high thermodynamic surface adsorption 59 and specific thermodynamics adsorption and redox reduction mechanism with GOx.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…An innovative glucose biosensor, developed by Devasenathipathy et al, 30 involved the coupling of biopolymer pectin-stabilized AuNPs electrodeposited on graphene and multiwalled carbon nanotubes (GR-MWCNTs/AuNPs) as shown in Figure 4. The biosensor was prepared by adding multiwalled carbon nanotubes (MWCNTs) in graphite oxide (GO) and ultrasonicating them to obtain GO-MWCNTs.…”
mentioning
confidence: 99%