2020
DOI: 10.5194/jsss-9-383-2020
|View full text |Cite
|
Sign up to set email alerts
|

Glass electrode half-cells for measuring unified pH in ethanol–water mixtures

Abstract: Abstract. The acidities of any given solvent or mixtures thereof can be compared by pH measurements on a unified scale, so-called pHabsH2O measurements. The method is quite new and has not been characterized with respect to metrological criteria to date. Metal solid-contact glass electrode half-cells, three commercial, conventional glass electrode half-cells with inner liquid filling and one pair of combined electrodes were used to investigate the stability of the measurement and the reproducibility of pHabsH2… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
16
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(18 citation statements)
references
References 9 publications
2
16
0
Order By: Relevance
“…However, the SCGE used here is not commercially available on a large scale. Similar advantages may be seen in other commercial half-cell electrodes for measurements [ 20 ]. However, differences between commercial electrodes have been noted when measuring solvent-specific pHe in anhydrous and hydrous bio-ethanol according to ASTM D6423-14 [ 26 , 27 ], as well as buffered methanol–water and ethanol–water solutions [ 28 ].…”
Section: Introductionmentioning
confidence: 58%
See 4 more Smart Citations
“…However, the SCGE used here is not commercially available on a large scale. Similar advantages may be seen in other commercial half-cell electrodes for measurements [ 20 ]. However, differences between commercial electrodes have been noted when measuring solvent-specific pHe in anhydrous and hydrous bio-ethanol according to ASTM D6423-14 [ 26 , 27 ], as well as buffered methanol–water and ethanol–water solutions [ 28 ].…”
Section: Introductionmentioning
confidence: 58%
“…SCGE (electrode A) differential potentiometry have previously been shown to allow the determination of values for buffered aqueous solutions described in the [ 25 ] and solvent–water [ 19 , 20 , 49 , 50 ] mixtures, as well as p K a values in acetonitrile [ 51 ]. The use of these electrodes in Cell I has been agreed to be the ‘reference’ method for value determination [ 36 ].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations