2022
DOI: 10.1007/s11033-022-07355-8
|View full text |Cite
|
Sign up to set email alerts
|

GhCDNC and GhCYP706B1 genes mediate gossypol biosynthesis in upland cotton

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 37 publications
0
4
0
Order By: Relevance
“…Twenty μL final volume of PCR reactions containing 12.8 μL ddH 2 O, 1 μL cDNA (20 ng/μL) as reported by Maryam et al [ 14 ], 0.4 μL of each primer (10 μM) (list of primers are given in Table 3 ), 2 μL rTaq buffer (10×), 1.6 μL MgCl 2 (25 mM), 1.6 μL dNTPs (10 mM), and 0.2 μL rTaq DNA polymerase (5 U/μL) (Takara Bio Inc.; Shiga, Japan). PCR was performed in a thermo-cycler (T100 Thermal Cycler, Bio-Rad Laboratories, Inc., Hercules, CA, USA) set with an initial denaturation temperature of 94 °C for 3 min, 35 cycles of denaturation at 94 °C for 30 s, annealing at 50–60 °C for 30 s and extension at 72 °C for 60 s/kb of amplicon followed by a final extension at 72 °C for 3 min/kb of the amplicon.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Twenty μL final volume of PCR reactions containing 12.8 μL ddH 2 O, 1 μL cDNA (20 ng/μL) as reported by Maryam et al [ 14 ], 0.4 μL of each primer (10 μM) (list of primers are given in Table 3 ), 2 μL rTaq buffer (10×), 1.6 μL MgCl 2 (25 mM), 1.6 μL dNTPs (10 mM), and 0.2 μL rTaq DNA polymerase (5 U/μL) (Takara Bio Inc.; Shiga, Japan). PCR was performed in a thermo-cycler (T100 Thermal Cycler, Bio-Rad Laboratories, Inc., Hercules, CA, USA) set with an initial denaturation temperature of 94 °C for 3 min, 35 cycles of denaturation at 94 °C for 30 s, annealing at 50–60 °C for 30 s and extension at 72 °C for 60 s/kb of amplicon followed by a final extension at 72 °C for 3 min/kb of the amplicon.…”
Section: Methodsmentioning
confidence: 99%
“…PCR was performed in a thermo-cycler (T100 Thermal Cycler, Bio-Rad Laboratories, Inc., Hercules, CA, USA) set with an initial denaturation temperature of 94 °C for 3 min, 35 cycles of denaturation at 94 °C for 30 s, annealing at 50–60 °C for 30 s and extension at 72 °C for 60 s/kb of amplicon followed by a final extension at 72 °C for 3 min/kb of the amplicon. Resolve amplicons on 1% agarose gel [ 14 , 15 ]. The band intensity was identified on ImageJ software ( accessed on 6 December 2021) [ 16 ].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations