Fundamentals of sinusoidal flow sequential injection spectrophotometry

Abstract: A rational design of the sequential injection analyzer is based on description of the mutual penetration of sample and reagent zones, which are sequentially stacked into a tubular conduit and then injected into a reactor and transported toward the detector by means of a carrier stream, flowing at a preprogrammed rate. Variables governing zone penetration have been identified by a series of dispersion experiments, for sequential injection of two and three zones, thus outlining the conditions for performing sing… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
65
0
16

Year Published

1995
1995
2011
2011

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 142 publications
(86 citation statements)
references
References 7 publications
5
65
0
16
Order By: Relevance
“…7 Increase in sample volume enhances the sensitivity of the measurements only if excess of reagent is fed to the sample zone. Thus, for sample volumes as large as the ones leading to 1 < D < 2, sandwiching the sample between reagent zones is recommended.…”
Section: Sample To Reagent Volume Ratios and Dispersionmentioning
confidence: 99%
See 2 more Smart Citations
“…7 Increase in sample volume enhances the sensitivity of the measurements only if excess of reagent is fed to the sample zone. Thus, for sample volumes as large as the ones leading to 1 < D < 2, sandwiching the sample between reagent zones is recommended.…”
Section: Sample To Reagent Volume Ratios and Dispersionmentioning
confidence: 99%
“…A typical system is configured in single line by a syringe pump, coupled to a two-way valve that can communicate with the carrier or with a multiport valve through a holding coil where the reaction zone is formed prior to injection toward the detector, placed in another port of the multiport valve, immediately after the reaction coil. 7 The optimization process can be laborious and take a long time, depending on the chosen route and variables considered in the process. The whole process may be simplified by an initial evaluation of sample dispersion and mixing efficiency using a dye solution in place of either sample or reagent.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Revertendo-se a direção do fluxo, as zonas são transportadas em direção ao detector através de uma bobina de reação, cuja função é garantir um percurso analítico mínimo para a sobreposição das zonas por efeitos de dispersão causados por difusão axial e radial, assim como da convecção. Um estudo sobre estes processos de dispersão e difusão foi detalhado por Gübeli et al 7 Toda a operação é controlada por um computador que disponha de programa específico para o SIA. As partes do sistema (indicadas pela linha tracejada na Figura 1) tornam-se então gerenciáveis pelo operador, exclusivamente através da interface computadorizada.…”
Section: Características E Operaçãounclassified
“…[9][10][11] And, Economou reviewed SIA for on-line sample handling and pretreatment. 12 Figure 1(b) shows a mini-conduit module with a flow cell and a fiber optics mounted atop a multi-port valve, called SI-Lab-on-Valve.…”
Section: Introductionmentioning
confidence: 99%