Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370)
DOI: 10.1109/ias.1999.801601
|View full text |Cite
|
Sign up to set email alerts
|

Frequency domain analysis of three phase linear current regulators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
30
0

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 336 publications
(39 citation statements)
references
References 5 publications
0
30
0
Order By: Relevance
“…The principle scheme of p q i i − detection method is shown in Fig.3. In the p q i i − detection method, only sin t ω , cos t ω − do take part in computing, and the harmonics of power grid distortion don't, so the detection result isn't effected by the distortion voltage of power grid, which warrants the detection result of three-phase harmonic and reactive component accurate in the case of non-sinusoidal or nonsymmetric three-phase voltage [17]. The method is realized by analog circuit conventionally, which is complex in the hardware and is restricted in the precision.…”
Section: B the Detection Methods Of Reactive Power And Harmonic Currentmentioning
confidence: 99%
“…The principle scheme of p q i i − detection method is shown in Fig.3. In the p q i i − detection method, only sin t ω , cos t ω − do take part in computing, and the harmonics of power grid distortion don't, so the detection result isn't effected by the distortion voltage of power grid, which warrants the detection result of three-phase harmonic and reactive component accurate in the case of non-sinusoidal or nonsymmetric three-phase voltage [17]. The method is realized by analog circuit conventionally, which is complex in the hardware and is restricted in the precision.…”
Section: B the Detection Methods Of Reactive Power And Harmonic Currentmentioning
confidence: 99%
“…controllers could be implemented either as PR regulators in the abc stationary frame, or as PI regulators in the dq synchronous rotating frame (the two methods are actually equivalent as has been shown in [12]). However, the central precept of the current regulation strategy presented in this paper is to deliberately operate the PR controller away from its tuned resonant frequency to achieve a current regulator phase shift error.…”
Section: Power Sharing With Unequal Power Ratingsmentioning
confidence: 99%
“…The capacitor voltage is first converted to equivalent stationary frame signals V α , V b then these are compared with the Stationary frame reference signals V α *, V b * and an errors e α and e b are generated which is given to the sinusoidal signal integrator [5]. The outputs of this voltage compensator I α , I b are then fed to an inner capacitor current compensator, acting as the capacitor current reference signals for this inner compensator.…”
Section: A Inner Voltage and Current Control Loopsmentioning
confidence: 99%