2006
DOI: 10.1016/j.ijms.2006.04.009
|View full text |Cite
|
Sign up to set email alerts
|

Formation of hydrated triply charged metal ions from aqueous solutions using nanodrop mass spectrometry

Abstract: Forming hydrated clusters containing triply charged metal ions is challenging due to the competing process of dissociation by forming the metal hydroxide with one less net charge and a protonated water molecule. It is demonstrated for the first time that it is possible to form such clusters using a method we call "nanodrop mass spectrometry". Clusters of the form [M(H 2 O) n ] 3+ , where M = Ce, Eu, and La, are generated using electrospray ionization and are mass analyzed in a Fourier-transform ion cyclotron r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
89
0

Year Published

2007
2007
2013
2013

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 58 publications
(90 citation statements)
references
References 37 publications
(84 reference statements)
1
89
0
Order By: Relevance
“…Experiments were performed on a 2.75 T Fourier transform ion cyclotron resonance (FT/ICR) mass spectrometer [31] equipped with an ion cell that is cooled to 133 K using a controlled flow of N 2 (l) [32]. Hydrated ions are formed from aqueous solutions of ϳ1 to 10 mM of the metal ion of interest using an external nanoelectrospray ionization source [31].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Experiments were performed on a 2.75 T Fourier transform ion cyclotron resonance (FT/ICR) mass spectrometer [31] equipped with an ion cell that is cooled to 133 K using a controlled flow of N 2 (l) [32]. Hydrated ions are formed from aqueous solutions of ϳ1 to 10 mM of the metal ion of interest using an external nanoelectrospray ionization source [31].…”
Section: Methodsmentioning
confidence: 99%
“…Hydrated ions are formed from aqueous solutions of ϳ1 to 10 mM of the metal ion of interest using an external nanoelectrospray ionization source [31]. The nanospray emitters are produced from borosilicate capillaries pulled to an inner tip diameter of ϳ1-2 m. A potential of ϩ500 to ϩ700 V (relative to the ϳ80 -100°C heated capillary entrance to the mass spectrometer) is applied to a platinum wire that is in contact with the solution.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This instrument, which has a temperature controlled ion cell that can be cooled using a regulated flow of liquid N 2 [48] and an electrospray ionization source that is used to produce extensively hydrated ions [49] is described in detail elsewhere. Hydrated divalent calcium and magnesium ions were formed by nanospray from aqueous solutions that are 2 mM in metal ion (from CaCl 2 and MgSO 4 ).…”
Section: Instrument and Methodsmentioning
confidence: 99%
“…The resulting cluster distributions are typically broad (Figure 2a) and can be shifted to either larger or smaller cluster size by changing instrumental parameters [49]. Low abundances of CaOH(H 2 O) n ϩ and H(H 2 O) n ϩ are also observed under these conditions.…”
Section: Precursor Activationmentioning
confidence: 99%