Forceps-Induced Scratching of a Foldable Acrylic Intraocular Lens
Search citation statements
Order By: Relevance
Paper Sections
Select...
20
4
2
1
Citation Types
0
11
0
3
Year Published
Range
1996
19962023
2023Publication Types
Select...
27
Relationship
0
27
Authors
Journals
Cited by 27 publications
(14 citation statements)
References 0 publications
0
11
0
3
Order By: Relevance
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…Silicone IOLs react with the silicone oil used in vitreoretinal surgery, 1,2 and hydrophobic acrylic IOLs can scratch and develop glistenings. 3,4 Hydrophilic acrylic IOLs, on the other hand, present the problem of opacification.…”
Section: Results
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…Silicone IOLs react with the silicone oil used in vitreoretinal surgery, 1,2 and hydrophobic acrylic IOLs can scratch and develop glistenings. 3,4 Hydrophilic acrylic IOLs, on the other hand, present the problem of opacification.…”
Section: Results
mentioning
confidence: 99%
Smart CitationsHow this paper cites the one you are viewing
“…According to available clinical and experimental literature, mechanical damage of foldable IOLs occurring during handling seems to be a relatively rare incident. Cracking of lens optics 1 , 2 , 3 or minor microlesions of IOL surfaces 4 , 5 , 6 , 7 caused by the use of folding or implantation forcipes was described in only a few cases. Nearly similar minor surface lesions were observed after passage of IOLs through injectors 8 , 9 , 10 .…”
Section: Discussion
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…This folding technique can also cause scratches and irreversible imprints on the center of the IOL optic. 28,29 In this study, we present a modification of the 4-flanged technique using a 4 eyelet IOL inserted through a standard 2.4 mm corneal incision. In this technique, the Akreos IOL AO60 with its original cartridge is easily inserted through the corneal incision, as would have been done in a routine cataract case.…”
Section: Discussion
mentioning
confidence: 99%
“…This folding technique can also cause scratches and irreversible imprints on the center of the IOL optic. 28,29…”
Section: Discussion
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…Silicone IOLs react with the silicone oil used in vitreoretinal surgery, 1,2 and hydrophobic acrylic IOLs can scratch and develop glistenings. 3,4 Hydrophilic acrylic IOLs, on the other hand, present the problem of opacification.…”
Section: Results
mentioning
confidence: 99%
Smart CitationsHow this paper cites the one you are viewing
“…According to available clinical and experimental literature, mechanical damage of foldable IOLs occurring during handling seems to be a relatively rare incident. Cracking of lens optics 1 , 2 , 3 or minor microlesions of IOL surfaces 4 , 5 , 6 , 7 caused by the use of folding or implantation forcipes was described in only a few cases. Nearly similar minor surface lesions were observed after passage of IOLs through injectors 8 , 9 , 10 .…”
Section: Discussion
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…This folding technique can also cause scratches and irreversible imprints on the center of the IOL optic. 28,29 In this study, we present a modification of the 4-flanged technique using a 4 eyelet IOL inserted through a standard 2.4 mm corneal incision. In this technique, the Akreos IOL AO60 with its original cartridge is easily inserted through the corneal incision, as would have been done in a routine cataract case.…”
Section: Discussion
mentioning
confidence: 99%
“…This folding technique can also cause scratches and irreversible imprints on the center of the IOL optic. 28,29…”
Section: Discussion
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…Silicone IOLs react with the silicone oil used in vitreoretinal surgery, 1,2 and hydrophobic acrylic IOLs can scratch and develop glistenings. 3,4 Hydrophilic acrylic IOLs, on the other hand, present the problem of opacification.…”
Section: Results
mentioning
confidence: 99%
Smart CitationsHow this paper cites the one you are viewing
“…According to available clinical and experimental literature, mechanical damage of foldable IOLs occurring during handling seems to be a relatively rare incident. Cracking of lens optics 1 , 2 , 3 or minor microlesions of IOL surfaces 4 , 5 , 6 , 7 caused by the use of folding or implantation forcipes was described in only a few cases. Nearly similar minor surface lesions were observed after passage of IOLs through injectors 8 , 9 , 10 .…”
Section: Discussion
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…This folding technique can also cause scratches and irreversible imprints on the center of the IOL optic. 28,29 In this study, we present a modification of the 4-flanged technique using a 4 eyelet IOL inserted through a standard 2.4 mm corneal incision. In this technique, the Akreos IOL AO60 with its original cartridge is easily inserted through the corneal incision, as would have been done in a routine cataract case.…”
Section: Discussion
mentioning
confidence: 99%
“…This folding technique can also cause scratches and irreversible imprints on the center of the IOL optic. 28,29…”
Section: Discussion
mentioning
confidence: 99%