2021 IEEE Workshop on Electrical Machines Design, Control and Diagnosis (WEMDCD) 2021
DOI: 10.1109/wemdcd51469.2021.9425678
|View full text |Cite
|
Sign up to set email alerts
|

Flux-Map Based FEA Evaluation of Synchronous Machine Efficiency Maps

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…This operating point is the most interesting, since the highest losses are generated in the rotor core and permanent magnets, for which the cooling method is required. The software package Syr-e [19] was used to model the electromagnetic aspects and losses generated in the machine, where the AC losses of the simulated loss maps are rescaled based on the difference with the available total loss map from the manufacturer. The used losses are shown in TABLE V. These losses are distributed uniformly over the volume of the components Within the comparison a circumferential jacket cooling with water-glycol at 40°C is present in the housing and an oil flow rate of 10 l/min is used at an inlet temperature of 60°C for the hollow shaft and direct rotor cooling.…”
Section: Model Validation and Thermal Performancementioning
confidence: 99%
“…This operating point is the most interesting, since the highest losses are generated in the rotor core and permanent magnets, for which the cooling method is required. The software package Syr-e [19] was used to model the electromagnetic aspects and losses generated in the machine, where the AC losses of the simulated loss maps are rescaled based on the difference with the available total loss map from the manufacturer. The used losses are shown in TABLE V. These losses are distributed uniformly over the volume of the components Within the comparison a circumferential jacket cooling with water-glycol at 40°C is present in the housing and an oil flow rate of 10 l/min is used at an inlet temperature of 60°C for the hollow shaft and direct rotor cooling.…”
Section: Model Validation and Thermal Performancementioning
confidence: 99%
“…Generally, a large number of finite-element simulations is used to create flux-linkage "maps" of 𝜆 𝑑 and 𝜆 𝑞 on the (𝐼 𝑑 , 𝐼 𝑞 ) plane. In [19], a 15 × 15 mesh of (𝐼 𝑑 , 𝐼 𝑞 ) points were used. The fluxlinkage maps can also be found experimentally.…”
Section: Finite-element Mappingmentioning
confidence: 99%
“…The procedure of iron loss estimation using FE-based model of the SynRel is based on the Steinmetz equation [24]:…”
Section: Iron Loss Estimation By Co-simulation Modelmentioning
confidence: 99%