2001
DOI: 10.2116/analsci.17.535
|View full text |Cite
|
Sign up to set email alerts
|

Fluorescent Derivatization of Nitrite Ions with 2,3-Diaminonaphthalene Utilizing a pH Gradient in a Y-shaped Microchannel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2002
2002
2015
2015

Publication Types

Select...
7
2
1

Relationship

1
9

Authors

Journals

citations
Cited by 29 publications
(7 citation statements)
references
References 24 publications
0
7
0
Order By: Relevance
“…SO2 was collected into the liquid phase in the crossed area, and the conductivities before and after the collection area were measured. A fluorometric NO2 determination system 90 with a porous glass plate scrubber 91 and a Y-shaped microchannel reactor 92 has been developed by Korenaga's group. In the Y-shaped channel reactor, the analyte reacts with the reagent under acidic conditions and the product diffuses into the alkaline region to emit fluorescence.…”
Section: ·8 Microscrubbermentioning
confidence: 99%
“…SO2 was collected into the liquid phase in the crossed area, and the conductivities before and after the collection area were measured. A fluorometric NO2 determination system 90 with a porous glass plate scrubber 91 and a Y-shaped microchannel reactor 92 has been developed by Korenaga's group. In the Y-shaped channel reactor, the analyte reacts with the reagent under acidic conditions and the product diffuses into the alkaline region to emit fluorescence.…”
Section: ·8 Microscrubbermentioning
confidence: 99%
“…Recently, we developed a similarly small, simple and highly sensitive air pollutant monitor by applying lab-on-a-chip technology to environmental air monitoring. [15][16][17][18][19] This lab-on-a-chip device integrates three functions, gas absorption, 15,16 fluorescence derivatization, 17,18 and fluorometric detection. 19 Although this microchip was initially designed based on the research of Odake et al, 17 the sensitivity of the original device was deemed too low to determine atmospheric NO 2 .…”
Section: Introductionmentioning
confidence: 99%
“…Various methods have been used for the determination of nitrite, including chromatography, 4-7 gas chromatography-mass spectrometry, 8 capillary electrophoresis, [9][10][11] colorimetric methods, [12][13][14][15][16][17][18][19][20][21][22][23] catalytic-based methods, [24][25][26] and several other methods such as electrochemical ones, 27-29 fluorometric ones 30,31 and chemiluminescence. [32][33][34] Flow injection analysis (FIA) in combination with one of the above detection methods have been widely used for the determination of nitrite.…”
Section: Introductionmentioning
confidence: 99%