Volume 2: Heat Transfer Enhancement for Practical Applications; Fire and Combustion; Multi-Phase Systems; Heat Transfer in Elec 2012
DOI: 10.1115/ht2012-58048
|View full text |Cite
|
Sign up to set email alerts
|

Flow Pattern and Pipe Orientation Independent Semi-Empirical Void Fraction Correlation for a Gas-Liquid Two Phase Flow Based on the Concept of Drift Flux Model

Abstract: A flow pattern and pipe orientation independent void fraction correlation is proposed in the present study. The correlation is based on the concept of drift flux model and proposes two separate expressions to model distribution parameter and drift velocity. The distribution parameter is expressed as a function of pipe orientation, phase superficial velocities and the void fraction in implicit form, while the drift velocity parameter is modeled as a function of fluid thermo physical properties, pipe orientation… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
12
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
2
1
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(12 citation statements)
references
References 35 publications
0
12
0
Order By: Relevance
“…For the lowest range of void fraction in vertical upward flow, the correlation of [86] gives best performance and predicts 89 % of data points within ±30 % error bands. The correlation of [12] also gives comparable performance for the first three ranges of void fraction i.e., for a B 0.75. Similar to vertical upward flow, for the last range of void fraction in vertical upward flow [25,105] are among the top performers.…”
Section: Performance Assessment Of Two Phase Void Fraction Correlationsmentioning
confidence: 58%
See 4 more Smart Citations
“…For the lowest range of void fraction in vertical upward flow, the correlation of [86] gives best performance and predicts 89 % of data points within ±30 % error bands. The correlation of [12] also gives comparable performance for the first three ranges of void fraction i.e., for a B 0.75. Similar to vertical upward flow, for the last range of void fraction in vertical upward flow [25,105] are among the top performers.…”
Section: Performance Assessment Of Two Phase Void Fraction Correlationsmentioning
confidence: 58%
“…It is observed that the correlation of [105] gives consistent and superior performance in all three ranges of the void fraction. Although the accuracy of [12] correlation is not comparable with the other top performing correlations listed in Table 4.9, it is evident that this correlation gives comparable performance for the first two ranges of the void fraction. Overall it is found that for refrigerant two phases flow, even the top performing correlations have limited success in prediction of the void fraction for 0 \ a B 0.5 and 0.5 \ a B 0.75.…”
Section: Performance Assessment Of Two Phase Void Fraction Correlationsmentioning
confidence: 61%
See 3 more Smart Citations