Flexural behavior of environmentally friendly ultra-high-performance concrete with locally available low-cost synthetic fibers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
11
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(12 citation statements)
references
References 36 publications
0
11
0
1
Order By: Relevance
“…The literature review shows that substituting some of the Portland cement with GP diminishes the resistance to bending in plain UHPC formulations [15,62]. However, while it is notable that the flexural strength lowers with increasing substitution of GP in the case of plain UHPC, it is important to recognize that in fiber-reinforced UHPC, the primary determinant of performance is the fiber reinforcement system [126][127][128].…”
Section: Flexural Behaviormentioning
confidence: 99%
See 2 more Smart Citations
“…The literature review shows that substituting some of the Portland cement with GP diminishes the resistance to bending in plain UHPC formulations [15,62]. However, while it is notable that the flexural strength lowers with increasing substitution of GP in the case of plain UHPC, it is important to recognize that in fiber-reinforced UHPC, the primary determinant of performance is the fiber reinforcement system [126][127][128].…”
Section: Flexural Behaviormentioning
confidence: 99%
“…However, while it is notable that the flexural strength lowers with increasing substitution of GP in the case of plain UHPC, it is important to recognize that in fiber-reinforced UHPC, the primary determinant of performance is the fiber reinforcement system [126][127][128]. Neira-Medina et al [15] researched to analyze the impact of different fiber-reinforced systems on the flex- The study also established that concrete of superior quality typically exhibits an ultrasonic pulse velocity exceeding 4575 m/s. As illustrated in Figure 10, the Control dosage reaches the threshold value after seven days of curing, while Optimized 1 requires 28 days, and Optimized 2 necessitates 90 days to achieve a similar threshold value.…”
Section: Flexural Behaviormentioning
confidence: 99%
See 1 more Smart Citation
“…Furthermore, multiple research projects have been conducted to explore the impact and synergistic effects of various SCMs, in addition to SF, in the construction of environmentally friendly RPC concrete [38,40,41]. Based on the foregoing findings, it is reasonable to conclude that GP offers the potential as a viable option for traditional materials in the development of RPC [42,43].…”
Section: Introductionmentioning
confidence: 96%
“…Los materiales cementantes suplementarios (MCS) son aquellos que por sus propiedades pueden ser utilizados en la industria del hormigón en la sustitución parcial del cemento [9,10]. Dentro de éstos, podemos encontrar dos grupos.…”
unclassified