First serial in vivo results of mechanical circulatory support in children with a new diagonal pump

Abstract: The use of the Deltastream DP3 seems to be safe and effective for MCS in children and may show a low degree of haemolysis. We observed no system-related complications and an overall good outcome in this demanding patient cohort.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
26
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(28 citation statements)
references
References 17 publications
1
26
1
Order By: Relevance
“…18,25 Compared with other studies, our pediatric patient cohort was heterogeneous comprising patients with pulmonary, postcardiotomy and other support indications, with both single and biventricular morphology. Of all seven patients with isolated respiratory support, only one patient with myelodysplastic syndrome (patient 20) could not be weaned from the device.…”
Section: Outcomementioning
confidence: 99%
“…18,25 Compared with other studies, our pediatric patient cohort was heterogeneous comprising patients with pulmonary, postcardiotomy and other support indications, with both single and biventricular morphology. Of all seven patients with isolated respiratory support, only one patient with myelodysplastic syndrome (patient 20) could not be weaned from the device.…”
Section: Outcomementioning
confidence: 99%
“…46 In this experiment, a slight to moderate hemolysis occurred induced by the ExMeTrA oxygenator using an integrated pulsatile pump by collapsing and expanding silicone tubes placed in the fiber bundle in combination with active valves. 20,39,47,48 In conclusion, our study analyzed the feasibility and hemocompatibility of a novel pediatric oxygenator with integrated Figure 4: Blood flow stayed stable over the time of ECC. Blood flow was measured using a flow meter behind the ExMeTrA oxygenator at the beginning of the ECC and after 1, 5, 10, 20, 30, 60, 120, 270, and 360 min.…”
Section: Figurementioning
confidence: 87%
“…decrease in platelet count and an increase in leukocyte count would be expected by sticking of platelets to the artificial surface of the oxygenator and tubing system and inflammatory responses. 14,39,40 During the entire experimental period, the concentration of total hemoglobin was on a very low level and extremely low red blood cell damage could be detected. Barrett et al 31 reported an increase in ECMO complications including hyperbilirubinemia, acute renal failure, and hemolysis in pediatric patients receiving ECMO support with a centrifugal pump.…”
Section: Figurementioning
confidence: 99%
“…In fact, a satisfactory hospital survival of nearly 40% as recorded herein does not allow ignoring that late mortality and permanent disability, particularly due to neurologic sequelae, are still observed after mechanical life support. Factors that may exacerbate these complications include the type of the pump itself (7,8,13), duration of support, components of the circuit, particularly the oxygenator, and exposure of red blood cells to sheer stress generated by the high negative or positive pressure (6), the surface of the tube circuit, and, possibly, nonphysiological conditions, such as the continuous, nonpulsatile flow (13)(14)(15)(16). Neonates, especially of low body weight, and young infants are uniquely vulnerable to ECMO-related complications, including neurologic injury, hemolysis, hyperbilirubinemia, hypertension, renal failure, and sustained systemic inflammatory response syndrome (5)(6)(7)(8).…”
Section: Discussionmentioning
confidence: 99%