2014
DOI: 10.1002/2014jd021829
|View full text |Cite
|
Sign up to set email alerts
|

First comparison of OMI‐DOAS total ozone using ground‐based observations at a megacity site in East Asia: Causes of discrepancy and improvement in OMI‐DOAS total ozone during summer

Abstract: This study compares, for the first time, the total ozone columns derived from the Ozone Monitoring Instrument-Differential Optical Absorption Spectroscopy (OMI-DOAS algorithm) (TOCs-OMI) with those obtained from ground-based Brewer and Dobson spectrophotometers (TOCs-Ground) in Seoul, a megacity in northeast Asia, over the 3 years between 2008 and 2010. We found a seasonal mean underestimation of 2.68% (maximum 18.33% on a single day) in TOCs-OMI when compared with TOCs-Ground from Seoul, particularly during t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1

Relationship

4
3

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 17 publications
0
5
0
2
Order By: Relevance
“…This Dobson was calibrated regularly against the standard instrument, with the most recent one done by NOAA in August-October 2014. The calibration history of this instrument was summarized by Kim et al (2007) and Hong et al (2014), and weekly regular standard lamp and monthly mercury lamp tests have been performed to check radiometric and spectral accuracy, respectively. Because of limitation in observation two to three times per day by the Dobson spectrophotometer (DBS hereafter), the TCO from the DBS has not been available to the diurnal variation of ozone amount.…”
Section: Dobson Spectrophotometer (Beck No 124)mentioning
confidence: 99%
See 2 more Smart Citations
“…This Dobson was calibrated regularly against the standard instrument, with the most recent one done by NOAA in August-October 2014. The calibration history of this instrument was summarized by Kim et al (2007) and Hong et al (2014), and weekly regular standard lamp and monthly mercury lamp tests have been performed to check radiometric and spectral accuracy, respectively. Because of limitation in observation two to three times per day by the Dobson spectrophotometer (DBS hereafter), the TCO from the DBS has not been available to the diurnal variation of ozone amount.…”
Section: Dobson Spectrophotometer (Beck No 124)mentioning
confidence: 99%
“…However, the ZS-measured TCO is based on the estimation value by the statistical regression approaches by comparing simultaneous observed TCO from DS and ZS under clear-sky conditions. For this reason, DS-measured TCO is more suitable for the comparison test than those from ZS (e.g., Hong et al, 2014;De Backer and De Muer, 1991;Balis et al, 2007). Although the ZS data are partially used from DBS due to its small observation number, the DS data are fully used from BRE for this analysis.…”
Section: Brewer Spectrophotometer (Sci-tec No 148)mentioning
confidence: 99%
See 1 more Smart Citation
“…특히 이산화황의 양 이 매우 높게 존재하는 화산 구름 내에서 TOMS 알고리 즘을 이용한 오존 산출에 이산화황이 영향을 주는 것으 로 보고되고 있다 (Krueger, 1983;McPeters et al, 1984;Korean Journal of Remote Sensing, Vol.32, No.6, 2016 -6 30 - Kroon et al, 2008;Choi et al, 2015). 로마, 프랑스, 스페인, 서울에서 이와 같은 유사한 비교 연구가 수행 된 바 있다 (Ialongo et al, 2008;Buchard et al, 2008;Antón et al,, 2009;Hong et al,, 2014). -6 32 - …”
Section: 각각 발사된 Meteorological Oprational Satellite (Metop)unclassified
“…또한, Differential Optical Absorption Spectroscopy (DOAS) 알고리즘이 위성측정 을 통한 오존 산출에 사용되어 왔다 (Bracher et al, 2005;Kroon et al, 2008;Loyola et al, 2011 (Bracher et al, 2005;Loyola et al, 2011). 현재는 2006 (Kroon et al, 2008 (Ialongo et al, 2008;Buchard et al, 2008;Antón et al, 2009;Hong et al, 2014).…”
Section: 서 론unclassified