2011
DOI: 10.1097/iae.0b013e3182019c18
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility of Intrasurgical Spectral-Domain Optical Coherence Tomography

Abstract: Intrasurgical spectral-domain optical coherence tomography evaluation is feasible using the tested system and may positively influence surgical decisions and techniques resulting in an improved patient outcome.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
113
0
4

Year Published

2012
2012
2022
2022

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 145 publications
(118 citation statements)
references
References 10 publications
1
113
0
4
Order By: Relevance
“…19,20 These systems provided the first insights of the potential of 'real-time' intraoperative OCT allowing for OCT-based visualization of instrument-tissue interaction and immediate imaging with surgeon feedback. 21,24 However, these systems also uncovered new challenges for intraoperative OCT development, including the need for new software systems, the limits of current instrumentation for OCT compatibility, and need for heads-up visualization. 19,21 In addition, the need for Z axis stabilization to maximize image visualization during surgical maneuvers was identified owing to the intermittent vertical displacement that occurs during surgical maneuvers.…”
Section: Intraoperative Oct Systems and Devicesmentioning
confidence: 99%
See 4 more Smart Citations
“…19,20 These systems provided the first insights of the potential of 'real-time' intraoperative OCT allowing for OCT-based visualization of instrument-tissue interaction and immediate imaging with surgeon feedback. 21,24 However, these systems also uncovered new challenges for intraoperative OCT development, including the need for new software systems, the limits of current instrumentation for OCT compatibility, and need for heads-up visualization. 19,21 In addition, the need for Z axis stabilization to maximize image visualization during surgical maneuvers was identified owing to the intermittent vertical displacement that occurs during surgical maneuvers.…”
Section: Intraoperative Oct Systems and Devicesmentioning
confidence: 99%
“…21,24 However, these systems also uncovered new challenges for intraoperative OCT development, including the need for new software systems, the limits of current instrumentation for OCT compatibility, and need for heads-up visualization. 19,21 In addition, the need for Z axis stabilization to maximize image visualization during surgical maneuvers was identified owing to the intermittent vertical displacement that occurs during surgical maneuvers. Methods for automated tracking and/or surgeon directed maneuvering of the OCT beam to areas of interest were also lacking.…”
Section: Intraoperative Oct Systems and Devicesmentioning
confidence: 99%
See 3 more Smart Citations