2019
DOI: 10.1016/j.zemedi.2018.10.005
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility of 4DCBCT-based proton dose calculation: An ex vivo porcine lung phantom study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
31
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 19 publications
(34 citation statements)
references
References 38 publications
2
31
0
Order By: Relevance
“…For more advanced applications, as for example 4DCBCT-based proton dose calculations, further improvements will be required to warrant sufficient image quality. 17 The finite range of protons and their sensitivity to changes in water equivalent thickness make it important to monitor variations in motion of the tumor and surrounding tissue. Especially when variations occur in the beam paths, at the distal edge or the lateral Medical Physics, 0 (0), xxxx penumbra regions.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…For more advanced applications, as for example 4DCBCT-based proton dose calculations, further improvements will be required to warrant sufficient image quality. 17 The finite range of protons and their sensitivity to changes in water equivalent thickness make it important to monitor variations in motion of the tumor and surrounding tissue. Especially when variations occur in the beam paths, at the distal edge or the lateral Medical Physics, 0 (0), xxxx penumbra regions.…”
Section: Discussionmentioning
confidence: 99%
“…MA‐ROOSTER reconstructed 4DCBCTs were found suitable in our opinion in the context of tumor motion assessment. For more advanced applications, as for example 4DCBCT‐based proton dose calculations, further improvements will be required to warrant sufficient image quality 17 . The finite range of protons and their sensitivity to changes in water equivalent thickness make it important to monitor variations in motion of the tumor and surrounding tissue.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In the future, this limitation might be overcome by introducing post-processed synthetic 4DCTs based on daily CBCTs suitable for proton dose calculations. There are multiple examples for developments towards introduction of 4DCBCTs [17] and synthetic CTs [18] which do have improved CT number accuracy that might make synthetic 4DCTs suitable for proton dose calculation. The initial investigations on the Table 3 CTV dose statistics based on reconstructed fraction doses and accumulated course dose.…”
Section: Limitationsmentioning
confidence: 99%