Fault-Tolerant Control of MMC With Hot Reserved Submodules Based on Carrier Phase Shift Modulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
40
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 108 publications
(40 citation statements)
references
References 28 publications
0
40
0
Order By: Relevance
“…When two SMs on the upper arm of phase A fault, the carrier phase shift angle of the bridge is changed to 2π/3, and the SM capacitance voltage reference value of the upper arm is set to 814/3 = 271 V, the carrier phase shift angle of the lower arm maintains 2π/5, each SM capacitor voltage reference value is changed to 210 V, according to Equation (22), as shown in Figure 5a. By contrast, in Figure 5b, when the symmetrical fault-tolerant control is adopted, the output voltage of inverter is only 4 levels, which is much less than the improved asymmetrical tolerance control in this paper.…”
Section: Analysis Of Simulation Results Of Two Sm Faults In Phase Amentioning
confidence: 99%
See 1 more Smart Citation
“…When two SMs on the upper arm of phase A fault, the carrier phase shift angle of the bridge is changed to 2π/3, and the SM capacitance voltage reference value of the upper arm is set to 814/3 = 271 V, the carrier phase shift angle of the lower arm maintains 2π/5, each SM capacitor voltage reference value is changed to 210 V, according to Equation (22), as shown in Figure 5a. By contrast, in Figure 5b, when the symmetrical fault-tolerant control is adopted, the output voltage of inverter is only 4 levels, which is much less than the improved asymmetrical tolerance control in this paper.…”
Section: Analysis Of Simulation Results Of Two Sm Faults In Phase Amentioning
confidence: 99%
“…A rotating sliding choice box adopted in a novel fault tolerant control strategy is proposed [22] to select the operating SMs, and guarantees the operation with a nearly seamless transition and very short recovery time. Meanwhile, the line cycle is set as the rotating period in the control method, without increasing much switching loss.…”
Section: Introductionmentioning
confidence: 99%
“…Two ways to implement Method-I have emerged, viz. [73]- [76] and [20], [27]- [31]. The main difference is the choice of the reference Vcijk* used by each SM capacitor voltage controller that ensures capacitor voltage balancing.…”
Section: A Method-i: Internal Voltage Control Scheme Based On Indivimentioning
confidence: 99%
“…Proposed PSRC method can be run at a low switching frequency range of 50 to 100 Hz and provides capacitor voltage balancing. New control strategy is presented in Li et al using hot reserved SMs with the help of PSC‐PWM modulation technique, which provides fault‐tolerant operation in a short recovery time and eliminates the undesired pulses.…”
Section: Control Conceptmentioning
confidence: 99%