Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
56
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 115 publications
(56 citation statements)
references
References 21 publications
0
56
0
Order By: Relevance
“…The experimentally obtained results are compared according to the analytical data from Figure 10. Figure 19 presents a comparison between the analytically estimated efficiency (1, 3) and experimental measurements (2,3). This result shows that the energy analysis given in Figures 7-10 can be assumed as valid with an acceptable error under 5%.…”
Section: Experimental Datamentioning
confidence: 82%
See 2 more Smart Citations
“…The experimentally obtained results are compared according to the analytical data from Figure 10. Figure 19 presents a comparison between the analytically estimated efficiency (1, 3) and experimental measurements (2,3). This result shows that the energy analysis given in Figures 7-10 can be assumed as valid with an acceptable error under 5%.…”
Section: Experimental Datamentioning
confidence: 82%
“…As this research is to offer more broad study, the presented data in Figures 6-9 and Table 2 are averages. It has been calculated from IGBT module datasheets, given in Table A1, using their basic parameters and the above presented equations (1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11). However, the interested reader could use specific IGBT modules for a more precise design of a Buck-Boost converter used as a battery charger or other applications.…”
Section: Buck Boostmentioning
confidence: 99%
See 1 more Smart Citation
“…It has been demonstrated that non-central and hierarchical control methods can provide the production balance of plants with power electronic-based inverters [57]. The requirement of communication infrastructure for the central control method, and redesigning if a new grid is installed, restricts the area of use of this control method [58]. The non-central control method is more appropriate for microgrids-since communication infrastructure is not necessary, it distributes the power more adequately for non-linear loads and works based on local measurements [59][60][61].…”
Section: Transient Stability In Grid-connected Microgridsmentioning
confidence: 99%
“…In [72], a two-stage optimization framework was developed to calculate the optimal capacity and power dispatch of a pair of wind and PV generations in an RE-based ECS system, in which an EV demand model was built using real EV data. In [73][74][75][76][77][78][79][80][81][82][83][84], the focuses were the control of ECSs with RE-based generation. A solid-state transformer was used in [73] for the energy management of PV-ECSs using a rule-based decision-making method, an energy-bound calculation (EBC) model, and a charging power allocation algorithm.…”
Section: Ecss With Resmentioning
confidence: 99%