2007
DOI: 10.1016/j.jbiomech.2006.11.012
|View full text |Cite
|
Sign up to set email alerts
|

Experimental validation of intact and implanted distal femur finite element models

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

4
22
0
1

Year Published

2007
2007
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 38 publications
(27 citation statements)
references
References 31 publications
4
22
0
1
Order By: Relevance
“…The standard deviations of principal strains obtained in this study were in the range of those calculated in the other experimental studies with synthetic femurs (e.g. Completo et al, 2007;Completo et al, 2008;Cristofolini and Viceconti, 1996;Viceconti et al, 2001;Waide et al, 2003).…”
Section: Discussionsupporting
confidence: 74%
See 1 more Smart Citation
“…The standard deviations of principal strains obtained in this study were in the range of those calculated in the other experimental studies with synthetic femurs (e.g. Completo et al, 2007;Completo et al, 2008;Cristofolini and Viceconti, 1996;Viceconti et al, 2001;Waide et al, 2003).…”
Section: Discussionsupporting
confidence: 74%
“…Several experimental studies with composite bones were carried out involving the measurement of bone surface strains. The main purpose of these was to respond to a clinical need in order to investigate in vitro implant-bone load transfer mechanisms, monitoring the strain shielding effect and for finite element model validation (Completo et al, 2007(Completo et al, , 2008Cristofolini and Viceconti, 1996;Viceconti et al, 2001;Waide et al, 2003). The standard deviations of principal strains obtained in this study were in the range of those calculated in the other experimental studies with synthetic femurs (e.g.…”
Section: Discussionmentioning
confidence: 67%
“…In this study was applied an identical experimental method described by Completo et al [24], with others synthetic models and strain measuring before and after implantation in the same femur model. Three synthetic femurs (third generation, left, mod.…”
Section: Methodsmentioning
confidence: 99%
“…Completo et al [24], on a previous experimental-numerical validation study measured strains in distal synthetic femur and compared to those obtained with numerical models, but did not compare strains changes (strain-shielding) before and after components implantation in the same femur model. The goal of the present study was to measure strain shielding in distal synthetic femurs with three different constructs of TKA.…”
Section: Introductionmentioning
confidence: 99%
“…Relating age and micro-architecture with apparent-level elastic constants: a micro-finite element study of female cortical bone from the anterior femoral midshaft 1 INTRODUCTION Numerous previous finite element (FE) studies have investigated the biomechanics of bone with orthopaedic implants; for example, fracture fixation [1][2][3], vertebral fixation [4], hip arthroplasty [5], and knee prostheses [6][7][8]. Depending on the outcome of interest, the results of such FE simulations may depend upon the specified elastic constants of bone tissues.…”
mentioning
confidence: 99%