2014
DOI: 10.1109/tdei.2014.004064
|View full text |Cite
|
Sign up to set email alerts
|

Experimental techniques to simulate naturally polluted high voltage transmission line insulators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
6
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 15 publications
1
6
0
Order By: Relevance
“…On the other hand, they hardly would be sedimented on the insulator surface. Therefore, a mix of (SPm) and salty dust, originated from MIGHAN Salt Lake and its surrounding desert, which is located 5 km northeast of the biggest city of the province, identified as the dominant air pollutant for the district under study [14], [15]. Consequently, a sample from the aforementioned mixture was gathered to be used as a substance for artificial pollution tests.…”
Section: Climate Evaluation and Determining The Dominant Air Pollution Constituentmentioning
confidence: 99%
“…On the other hand, they hardly would be sedimented on the insulator surface. Therefore, a mix of (SPm) and salty dust, originated from MIGHAN Salt Lake and its surrounding desert, which is located 5 km northeast of the biggest city of the province, identified as the dominant air pollutant for the district under study [14], [15]. Consequently, a sample from the aforementioned mixture was gathered to be used as a substance for artificial pollution tests.…”
Section: Climate Evaluation and Determining The Dominant Air Pollution Constituentmentioning
confidence: 99%
“…Because of certain influencing factors and constraints, it is difficult to choose a common form of insulation with satisfactory performance. For instance, the insulation capacity can be reduced if an insulating chain is exposed to polluted environments and then subjected to high humidity [1]. This initially leads to electric discharges where their severity and rate may increase, generating a complete line-to-ground discharge called ``bypass or flashover" [2].…”
Section: Introductionmentioning
confidence: 99%
“…Previous studies have used lab tests to determine the relationship between the deposit levels of soluble and non-soluble salts [9,10] and leakage currents under predefined working conditions [11,12] to obtain valuable information on the risk of electric arc onset. However, in real applications, a mixture of sediments whose composition varies over time is deposited on the insulator surface [9], which makes it difficult to determine the PLC level and its possible negative consequences on the insulator.…”
Section: Introductionmentioning
confidence: 99%