2022
DOI: 10.26434/chemrxiv-2022-xq73s-v2
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Expanding Orbitrap collision cross section measurements to native protein applications through kinetic energy and signal decay analysis

Abstract: The measurement of collision cross sections (CCS) offers supplemental information about sizes and conformations of ions beyond mass analysis alone. We have previously shown that CCSs can be determined directly from the time-domain transient decay of ions in an Orbitrap mass analyzer as ions oscillate around the central electrode and collide with neutral gas, thus removing them from the ion packet. Herein, we develop the soft sphere collision model, thus deviating from prior FT-MS CCS hard sphere model, to dete… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

1
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 60 publications
1
2
0
Order By: Relevance
“…Isotopic resolution is readily achieved for all proteins besides alcohol dehydrogenase and pyruvate kinase in Figure 3 and could be achieved for larger protein complexes by extending the acquisition time to increase the number of ions collected. 23 The Ecm correction factor determined herein showed stability over the course of the study (∼8 months), which is consistent with the correction factor developed by James et al 20 This approach may also be applied to previously collected data using DMTmode if sufficient ion decay was observed. Determining CCS by I 2 MS provides an orthogonal measurement that may be extracted from I 2 MS data sets without increasing the experimental time required, allowing for more detailed characterization of proteins and protein complexes with Orbitrap mass spectrometers.…”
Section: Data Analysis and Collision Cross Section Determinationsupporting
confidence: 86%
See 2 more Smart Citations
“…Isotopic resolution is readily achieved for all proteins besides alcohol dehydrogenase and pyruvate kinase in Figure 3 and could be achieved for larger protein complexes by extending the acquisition time to increase the number of ions collected. 23 The Ecm correction factor determined herein showed stability over the course of the study (∼8 months), which is consistent with the correction factor developed by James et al 20 This approach may also be applied to previously collected data using DMTmode if sufficient ion decay was observed. Determining CCS by I 2 MS provides an orthogonal measurement that may be extracted from I 2 MS data sets without increasing the experimental time required, allowing for more detailed characterization of proteins and protein complexes with Orbitrap mass spectrometers.…”
Section: Data Analysis and Collision Cross Section Determinationsupporting
confidence: 86%
“…Native CCS were determined using the collision energy correction in eq 2 as previously described by James et al 20 The center of mass collision energy (Ecm) for a protein charge state is used to estimate the percent difference between the Orbitrap CCS measurements and IMS CCS measurements to correct values from eq 1. Native CCS were ultimately After sampling, decay constants are extracted from the population decay plots.…”
Section: Data Analysis and Collision Cross Section Determinationmentioning
confidence: 99%
See 1 more Smart Citation