2009
DOI: 10.1007/s00431-009-0936-x
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Omron MX3 Plus monitor for blood pressure measurement in adolescents

Abstract: This study analyzed the accuracy/agreement of the Omron MX3 monitor on 165 adolescents. Blood pressure was measured by the automatic monitor connected in Y with the mercury column (three consecutive and simultaneous measures). The independent measures were analyzed, and the mean differences between systolic and diastolic measures for both methods were calculated and compared with British Hypertension Society (BHS) and Association for the Advancement of Medical Instrumentation (AAMI) criteria. The automatic mon… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
23
0
7

Year Published

2010
2010
2017
2017

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 31 publications
(30 citation statements)
references
References 22 publications
0
23
0
7
Order By: Relevance
“…Previous study has demonstrated good agreement between heart rate obtained using the Omron HEM 742 blood pressure monitoring device and a heart rate monitor [10]. RHR was categorized into normal (first to third quartile) and elevated (fourth quartile) RHR.…”
Section: Discussionmentioning
confidence: 99%
“…Previous study has demonstrated good agreement between heart rate obtained using the Omron HEM 742 blood pressure monitoring device and a heart rate monitor [10]. RHR was categorized into normal (first to third quartile) and elevated (fourth quartile) RHR.…”
Section: Discussionmentioning
confidence: 99%
“…The technical validity of these monitors has been confirmed previously in adults, children, and adolescents. [13][14][15] The midarm circumference was measured and the cuff width adapted accordingly (pediatric, standard adult, or oversized cuff for midarm circumference of 17 to 22, 22 to 32, or 32 to 42 cm, respectively). Systolic BP (SBP), diastolic BP (DBP), mean arterial pressure (MAP), and heart rate (HR) were calculated as the mean of the 3 measurements.…”
Section: Methodsmentioning
confidence: 99%
“…BP was measured by an oscillometric device Omron HEM-742 model, previously validated for use in adolescentes 22 . All subjects sat at rest for five minutes before the first measurement and the interval between the first and second assessment was of two minutes.…”
Section: Methodsmentioning
confidence: 99%