2002
DOI: 10.1049/ip-smt:20020131
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Guang Dong lightning location system with transmission line fault data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(12 citation statements)
references
References 9 publications
0
11
0
Order By: Relevance
“…The lightning data were from a lightning location system [Guangdong Lightning Location System (GDLLS); Chen et al 2004], which was put into operation in 1997 in the grid of Guangdong Electric Power Company. Chen et al (2002) of GDLLS with the data of recorded lightning faults on transmission lines in 1997-99, and found the DE is as high as 86% and the median LA is about 1.3 km. 1) and provides real-time CG lightning locations for the whole area of Guangdong province and its vicinity covered by the combined technique of magnetic direction finding (DF) and time of arrival (TOA).…”
Section: A Cg Lightning Datamentioning
confidence: 99%
“…The lightning data were from a lightning location system [Guangdong Lightning Location System (GDLLS); Chen et al 2004], which was put into operation in 1997 in the grid of Guangdong Electric Power Company. Chen et al (2002) of GDLLS with the data of recorded lightning faults on transmission lines in 1997-99, and found the DE is as high as 86% and the median LA is about 1.3 km. 1) and provides real-time CG lightning locations for the whole area of Guangdong province and its vicinity covered by the combined technique of magnetic direction finding (DF) and time of arrival (TOA).…”
Section: A Cg Lightning Datamentioning
confidence: 99%
“…Five LLS sensor stations were added in May 1999. After the 1999 upgrade, the detection efficiency for CG lightning flash was about 86% with an average location error approximately 1300 m [Chen et al, 2002]. Multistation observation technique was then used to increase the accuracy of detecting flashes position and the sensitivity of detecting lightning flashes.…”
Section: The South China Power Gird Lls and Performance In Prdmentioning
confidence: 99%
“…The LLS of the Guangdong power grid was originally built in 1997 (Chen et al 2002). The combined magneticdirection-finding and time-of-arrival (MDF-TOA) technology is used to detect CG lightning stroke information such as longitude and latitude, GPS time, peak current, polarity, reporting sensors, etc.…”
Section: A Lls Of the Guangdong Power Gridmentioning
confidence: 99%