2014
DOI: 10.1016/j.prosdent.2013.08.020
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the durability and antiadhesive action of 2-methacryloyloxyethyl phosphorylcholine grafting on an acrylic resin denture base material

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
44
0
4

Year Published

2014
2014
2020
2020

Publication Types

Select...
8
1

Relationship

4
5

Authors

Journals

citations
Cited by 52 publications
(61 citation statements)
references
References 17 publications
3
44
0
4
Order By: Relevance
“…Therefore, we hypothesized that zwitterionic polymer grafted layers would attract water molecules only and repel positively charged inorganic ions and negatively charged protein molecules and bacteria cells. Several previous studies have reported that the water molecules adsorbed on the surface of MPC polymers, e.g., poly(MPC-co-n-butyl methacrylate) (PMB) or PMPC, act as an antibiofouling layer to reduce the interaction between the surface and living organism [39,[43][44][45][46]. Fujii et al [43] and Takahashi et al [44] reported that PMB-coated and PMPC-grafted metal or polymer surfaces reduced bacteria adhesion.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, we hypothesized that zwitterionic polymer grafted layers would attract water molecules only and repel positively charged inorganic ions and negatively charged protein molecules and bacteria cells. Several previous studies have reported that the water molecules adsorbed on the surface of MPC polymers, e.g., poly(MPC-co-n-butyl methacrylate) (PMB) or PMPC, act as an antibiofouling layer to reduce the interaction between the surface and living organism [39,[43][44][45][46]. Fujii et al [43] and Takahashi et al [44] reported that PMB-coated and PMPC-grafted metal or polymer surfaces reduced bacteria adhesion.…”
Section: Discussionmentioning
confidence: 99%
“…43,44,47 Each disk was immersed in phosphate buffered saline (PBS) for 2 h before immersing in 4.5 g/L bovine serum albumin (BSA) (Sigma-Aldrich) solutions at 37 °C for 2 h. 43,44 The disks then were rinsed with fresh PBS by stirring method (300 rpm for 5 min). The adsorbed protein was detached in sodium dodecyl sulfate (SDS) 1 wt% in PBS by sonication for 20 min.…”
Section: Methodsmentioning
confidence: 99%
“…45,46 Previous study evaluated the durability and antiadhesive action of MPC grafting on an acrylic resin denture base material. 47 The results demonstrated that graft polymerization of MPC on denture surfaces contributed to the durability of the coating and prevented microbial retention. However, there has been no report on the application of MPC to the dentin bonding agents.…”
Section: Introductionmentioning
confidence: 94%
“…And our previous research confirmed that both ABWs and ZrO2 were added in PMMA with certain proportion, the results showed that they could improve the mechanical properties obviously 10,11) . Another clinical problem associated with self-curing acrylic resins is the adhesion of dental plaque formed by oral microorganisms due to the PMMA's high water absorption capacity, surface porosities and materia alba configuration 13) . Denture plaque is a source of infection and is responsible for a variety of clinical problems, including abutment caries, denture stomatitis and aspiration pneumonia 14) .…”
Section: Introductionmentioning
confidence: 99%