1997
DOI: 10.1093/oxfordjournals.rpd.a032009
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Dose Algorithm Based on the Scatter Model Applied for Neutron Therapy Treatment Planning

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
6
0

Year Published

2001
2001
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 0 publications
1
6
0
Order By: Relevance
“…The beam profile data collected for the nonfocused neutron beams were entered into the in-house treatment planning system, VRSPLAN,7,8 to create a neutron source with a nonfocused collimation system. Next, treatment plans were developed using the nonfocused beam for actual patients previously treated with neutron therapy at our center.…”
Section: B Treatment Planningmentioning
confidence: 99%
“…The beam profile data collected for the nonfocused neutron beams were entered into the in-house treatment planning system, VRSPLAN,7,8 to create a neutron source with a nonfocused collimation system. Next, treatment plans were developed using the nonfocused beam for actual patients previously treated with neutron therapy at our center.…”
Section: B Treatment Planningmentioning
confidence: 99%
“…For the social network information leakage-tracking algorithm, the current main research directions include the extraction of biometrics and the establishment of the trust model. At the level of corresponding biometric extraction, the mainstream extraction includes biometrics such as digital fingerprint, and the main research details include the research on relevant details such as digital fingerprint decoding, coded fingerprint, continuous fingerprint, and discrete fingerprint [ 24 , 25 ]. For the research on relevant aspects of the trust model, relevant researchers in the United States have proposed a trust model based on network structure, which mainly constructs a trust model based on high-density nodes in the network [ 26 ].…”
Section: Related Research: Analysis Of the Research Status Of Online ...mentioning
confidence: 99%
“…For the second part of this study, an in-house treatment planning system which uses the DSAR method was validated for IMNRT. Previous studies by Yudelev et al (1997) established the validity of this method for dose calculations in neutron beams. These have been reevaluated especially for smaller field sizes.…”
Section: Introductionmentioning
confidence: 94%
“…A dose modifying function which corrects for flatness, contour irregularities, beam filtering etc, was introduced into the dose calculation algorithm. Earlier studies by Yudelev et al validated this DSAR method for dose calculation using neutron beams (Yudelev et al 1997). They incorporated a multiplicative function called the profile function (PF) which is based on the beam profiles and includes any beam modifying factor (Yudelev et al 1997).…”
Section: Feasibility Of the Differential Scatter Air Ratio Model For ...mentioning
confidence: 99%
See 1 more Smart Citation