2009
DOI: 10.1016/j.corsci.2009.06.040
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of corrosion inhibition of brass-118 in artificial seawater by benzotriazole using Dynamic EIS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
46
0
3

Year Published

2010
2010
2018
2018

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 97 publications
(50 citation statements)
references
References 25 publications
0
46
0
3
Order By: Relevance
“…The use of these parameters, similar to the constant phase element (CPE), allowed the depressed feature of Nyquist plot to be reproduced readily. In addition, the effective calculated double layer capacitance (C dl ) derived from the CPE parameters according [34] to the following equation (6):…”
Section: Electrochemical Impedance Measurementsmentioning
confidence: 99%
“…The use of these parameters, similar to the constant phase element (CPE), allowed the depressed feature of Nyquist plot to be reproduced readily. In addition, the effective calculated double layer capacitance (C dl ) derived from the CPE parameters according [34] to the following equation (6):…”
Section: Electrochemical Impedance Measurementsmentioning
confidence: 99%
“…Clearly, in the UV/Cl 2 DWDS, the diameter of the impedance loops markedly increased with time, indicating a decrease of the corrosion rate after 50 d. However, in the Cl 2 alone DWDS, the diameters of impedance loops decreased from 50 d to 140 d, and later increased with time, indicating that the corrosion rate was accelerated before 140 d, then the corrosion rate decreased. Furthermore, according to a described method (Gerengi et al, 2009), all impedance spectra were analyzed with an equivalent circuit, where R s refers to resistance of electrolytes in bulk, Rct refers to charge transfer resistance at metal surface, W refers to Warburg impedance, Q refers to constant phase element of the electrical double layer (Fig. S6).…”
Section: Corrosion Process With Different Disinfectionmentioning
confidence: 99%
“…For all the studied compounds, the impedance diagrams display one single capacitive loop represented by a slightly depressed semicircle. This capacitive loop indicates that the corrosion of the alloys in 3%, 6% and 9% concentrations of Na 2 B 4 O 7 ·5H 2 O solution is mainly controlled by the charge transfer process and the formation of an adsorption layer on the metal surface [27]. All experimental spectra were fitted with an appropriate equivalent circuit (Figure 2) in order to find the parameters which described and were consistent with the experimental data.…”
Section: Electrochemical Impedance Measurementsmentioning
confidence: 99%