Evaluation of a differential mobility spectrometer/miniature mass spectrometer system

Abstract: A planar differential mobility spectrometer (DMS) was coupled to a Mini 10 handheld rectilinear ion trap (RIT) mass spectrometer (MS) (total weight 10 kg), and the performance of the instrument was evaluated using illicit drug analysis. Coupling of DMS (which requires a continuous flow of drift gas) with a miniature MS (which operates best using sample introduction via a discontinuous atmospheric pressure interface, DAPI), was achieved with auxiliary pumping using a 5 L/min miniature diaphragm sample pump plac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 18 publications
(8 citation statements)
references
References 15 publications
0
8
0
Order By: Relevance
“…History are examples in this area. Coupling of DMS to a field‐portable miniature mass spectrometer to serve as a simple pre‐separation device has been explored (Tadjimukhamedov et al, ). It offers the opportunity to increase the selectivity of the mass spectrometer without the cost and complexity of adding additional pumps, either liquid pumps in the case of LC or additional vacuum pumps if one were to consider a gain in the extra selectivity from tandem mass spectrometry.…”
Section: Applications Of Dms In Combined Systemsmentioning
confidence: 99%
“…History are examples in this area. Coupling of DMS to a field‐portable miniature mass spectrometer to serve as a simple pre‐separation device has been explored (Tadjimukhamedov et al, ). It offers the opportunity to increase the selectivity of the mass spectrometer without the cost and complexity of adding additional pumps, either liquid pumps in the case of LC or additional vacuum pumps if one were to consider a gain in the extra selectivity from tandem mass spectrometry.…”
Section: Applications Of Dms In Combined Systemsmentioning
confidence: 99%
“…We will list two examples. In Tadjimukhamedov et al (2010) from Prof. R. Graham Cooks lab at Purdue U., a standard Sionex DMS interface has been fitted to their mini-10.5 iontrap mass spectrometer (10 kg weight). Excellent results have been obtained for separation of morphine from diazepam (differing by 1 mass unit), and for measurements from biological samples.…”
Section: Large-scale Screening For Radiation Exposure Based On Metabomentioning
confidence: 99%
“…The capillary or skimmer interface can be used effectively only for offline disposable emitter applications, but this method is the most economical in sample usage and among the highest in ionization efficiency. A simple interface of the latter type was used in recent work in the Cooks group at Purdue on interfacing DMS to a small ion trap mass spectrometer with discontinuous sample introduction (Tadjimukhamedov et al 2010); it is likely that a reaction chamber or curtain gas interface could improve the performance and flexibility of DMS interfaces to this type of device, as it does for independent DMS detection.…”
Section: Resultsmentioning
confidence: 99%