2011
DOI: 10.1149/1.3554728
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of 316L Stainless Steel Corrosion Resistance in Solution Simulating the Acid Hydrolysis of Biomass

Abstract: The corrosion resistance of 316L stainless steel in 65 wt % ethanol, 35 wt % water, 1 wt % H 2 SO 4 solution containing different NaCl concentrations and at different temperatures was investigated using open circuit potential measurements, polarization curves, and electrochemical impedance spectroscopy. At 25 C, the minimum NaCl concentration required for occurrence of pitting was 0.58 wt %. In 0.35 wt % NaCl solution, localized corrosion was observed at temperatures higher than 40 C and, depending on the pote… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0
4

Year Published

2011
2011
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(15 citation statements)
references
References 52 publications
0
11
0
4
Order By: Relevance
“…31 Figures 2a, 2b, and 2c show the SEM micrographs for the polarized steel in the absence and presence of ethanol, respectively. According to X-ray microanalysis previously performed, 14 both images show MnS inclusion dissolution up to the transpassivation region (+1000 mV and +1500 mV vs. Ag/AgCl/KCl sat. ).…”
Section: Resultsmentioning
confidence: 74%
See 3 more Smart Citations
“…31 Figures 2a, 2b, and 2c show the SEM micrographs for the polarized steel in the absence and presence of ethanol, respectively. According to X-ray microanalysis previously performed, 14 both images show MnS inclusion dissolution up to the transpassivation region (+1000 mV and +1500 mV vs. Ag/AgCl/KCl sat. ).…”
Section: Resultsmentioning
confidence: 74%
“…Current density values higher than those obtained in the direct scan (before inverting the scan) indicate that the damaged passive film is not repaired and/or localized corrosion has started, while smaller current values reflect film repair under the same conditions, and therefore the pitting process (stable pit formation) is not initiated. 14 As can be seen in Figure 1, in the reverse scan, the current density decreased exponentially as the potential decreased, indicating that the current density increase in the direct scan was not associated with the localized corrosion, but with transpassivation of the steel.…”
Section: Resultsmentioning
confidence: 84%
See 2 more Smart Citations
“…1,9 As soluções foram preparadas a partir de reagentes com grau analítico e água Milli-Q (18,2 MΩ cm).…”
Section: Soluçõesunclassified