Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
1

Year Published

2011
2011
2018
2018

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 4 publications
0
3
0
1
Order By: Relevance
“…Commonly used absorption refrigeration working fluid pairs, ammonia/water and water/LiBr, have drawbacks including toxicity (ammonia), negative effects of crystallization (LiBr), incompatibility with metal components, and necessity for a rectifier for postdesorption separation of fluid streams [13]. Ethylene g,lycol/water were selected as working fluids in an experimental absorption cycle [14], however, water as a refrigerant has several disadvantages including high vapor pressure, subatmospheric pressure conditions and restricted temperature range in system operation. Ionic liquids (ILs) are a liquid salt at ambient temperature.…”
Section: Introductionmentioning
confidence: 99%
“…Commonly used absorption refrigeration working fluid pairs, ammonia/water and water/LiBr, have drawbacks including toxicity (ammonia), negative effects of crystallization (LiBr), incompatibility with metal components, and necessity for a rectifier for postdesorption separation of fluid streams [13]. Ethylene g,lycol/water were selected as working fluids in an experimental absorption cycle [14], however, water as a refrigerant has several disadvantages including high vapor pressure, subatmospheric pressure conditions and restricted temperature range in system operation. Ionic liquids (ILs) are a liquid salt at ambient temperature.…”
Section: Introductionmentioning
confidence: 99%
“…A wide variety of refrigerant/absorbent combinations have been suggested for absorption cooling systems [13], being the mixtures of water/LiBr and ammonia/water as the two most common working fluids [12]. However, both systems have their limitations, which make necessary to research different working pairs [14].…”
Section: Working Pairmentioning
confidence: 99%
“…Baseando-se nos artigos de Calva et al (2005), Collona e Gabrielli (2003) e Abdelmessih et al (2007) um sistema de trigeração foi montado objetivando-se estudar a influência de variáveis operacionais sobre a distribuição das utilidades geradas (calor, frio e potência), a fim de se atender a demandas típicas destas utilidades em diferentes processos industriais. A eficiência global do sistema e o coeficiente de desempenho (COP, do inglês "coefficient of performance") do ciclo de refrigeração por absorção também foram alvos de estudos, visando sua maximização.…”
Section: Metodologiaunclassified