2017
DOI: 10.1016/j.talanta.2017.05.007
|View full text |Cite
|
Sign up to set email alerts
|

Enzyme-free chemiluminescence immunoassay for the determination of thyroid stimulating hormone

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 27 publications
(12 citation statements)
references
References 30 publications
0
12
0
Order By: Relevance
“…At first, peroxyoxalate‐based chemiluminescence (POCL) is used in the field of emergency light sources, such as the well‐known light stick. Later, it was applied in analytical chemistry, and has been used in the biomedicine area since the 2000s [63–67] . Classical POCL involves a chemically initiated electron exchange luminescence mechanism [68,69] and a nonradiative dipole‐dipole energy transfer process [70] .…”
Section: Activatable Chemiluminescent Probesmentioning
confidence: 99%
“…At first, peroxyoxalate‐based chemiluminescence (POCL) is used in the field of emergency light sources, such as the well‐known light stick. Later, it was applied in analytical chemistry, and has been used in the biomedicine area since the 2000s [63–67] . Classical POCL involves a chemically initiated electron exchange luminescence mechanism [68,69] and a nonradiative dipole‐dipole energy transfer process [70] .…”
Section: Activatable Chemiluminescent Probesmentioning
confidence: 99%
“…These TSH conjugated microspheres showed enhanced chemiluminescence emission relative to unconjugated particles when treated with oxalyl diimidazole and H 2 O 2 . Thus, they could quantify TSH levels in blood serum more rapidly and sensitively than conventional immunoassays to date …”
Section: Application Of Peroxyoxalate CL Read‐outmentioning
confidence: 99%
“…These TSH conjugated microspheres showed enhanced chemiluminescence emission relative to unconjugated particles when treated with oxalyl diimidazole and H 2 O 2 .T hus, they could quantify TSH levels in blood serum more rapidly and sensitively than conventional immunoassays to date. [53] Although ar ange of fluorophores that can be used in PO-CL exist, there alwayss eems to be an interesti nf inding new and perhaps more efficient smallm olecule fluorophores. Recently, Kazemie tal.…”
Section: Nanomaterials and Po-clmentioning
confidence: 99%
“…With the rapid development of CLIA in recent years, CLIA has been widely used in the fields of life science research, drug analysis, medical clinical research, food analysis and detection, and animal medicine and environmental management; many important research results have been achieved using CLIA (19). (21).…”
Section: Introductionmentioning
confidence: 99%
“…With its high sensitivity and specificity, CLIA has continuously contributed to a new understanding of scientific technology and research fields (18). With the rapid development of CLIA in recent years, CLIA has been widely used in the fields of life science research, drug analysis, medical clinical research, food analysis and detection, and animal medicine and environmental management; many important research results have been achieved using CLIA (19). For example, Liu et al have established a CLIA method for proteins based on recombinant non-structural epitopes that accurately distinguishes cattle infected and inoculated with foot-and-mouth disease virus with high sensitivity (20).…”
Section: Introductionmentioning
confidence: 99%