2000
DOI: 10.1002/(sici)1099-114x(20000310)24:3<263::aid-er579>3.0.co;2-m
|Get access via publisher |Summarize |Cite
Entropic analysis of adsorption open cycles for air conditioning. Part 2: interpretation of experimental data
Search citation statements
Paper Sections
Select...
31
2
0
0
Citation Types
0
6
0
1
Year Published
2000
2026
Publication Types
Select...
27
5
1
Relationship
1
32
Authors
Journals
Cited by 33 publications
(7 citation statements)
References 20 publications
0
6
0
1
Smart CitationsHow this paper cites the one you are viewing
“…Especially, using exergy analysis based on the second law of thermodynamics can resolve the issue related to system efficiency in a more fundamental way by analyzing the cause of exergy destruction both in whole system and each component. (1,2) 제습 냉방시스템에 대한 선행연구로 Pons and Kodama (3) 는 냉방 공조를 위한 흡착식 개방형 사이 클에 대한 엔트로피 해석을 수행하였고 등 , Kodama (4) 은 이에 대한 실험적 연구를 진행하였으며, Chang and Lee (5) . 제습휠에서의 엑서지 파괴율은 식 와 같다 (5) .…”
Section: 기호설명 --
unclassifiedSmart CitationsHow this paper cites the one you are viewing
“…Especially, using exergy analysis based on the second law of thermodynamics can resolve the issue related to system efficiency in a more fundamental way by analyzing the cause of exergy destruction both in whole system and each component. (1,2) 제습 냉방시스템에 대한 선행연구로 Pons and Kodama (3) 는 냉방 공조를 위한 흡착식 개방형 사이 클에 대한 엔트로피 해석을 수행하였고 등 , Kodama (4) 은 이에 대한 실험적 연구를 진행하였으며, Chang and Lee (5) . 제습휠에서의 엑서지 파괴율은 식 와 같다 (5) .…”
Section: 기호설명 --
unclassifiedAbstract
Smart CitationsHow this paper cites the one you are viewing
“…Several studies of partial or complete solid desiccant systems for air conditioning have been conducted, mainly supported on experimental results [45,46] or using mathematical modelling with the behaviour of the desiccant device taken from proper laboratory experiments [47], manufacturer's performance data [48] or specific modelling software [49][50][51].…”
Section: Bi
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…Such systems, mostly designed for air-conditioning, are based either on adsorption (silicagel on a rotary wheel) or on liquid sorption (LiBr). A typical desiccant cooling system is schematically shown in Figure 1 [22]. The ambient atmosphere (#1 in Figure 1) is the heat sink at T c , the air-conditioned room (#5) is the lowtemperature (T e ) heat source of the cycle, and heat is supplied at T h to the heating system HS (#8).…”
Section: Open Cycles
mentioning
confidence: 99%
“…In ref. [22], the second law analysis of such cycles has been developed and applied to experimental data obtained at Kumamoto University. It shows Table 1 Analysis of the basic cycles: 1.…”
Section: Open Cycles
mentioning