2021
DOI: 10.1021/acs.langmuir.1c00905
|View full text |Cite
|
Sign up to set email alerts
|

Enhancing the Sensitivity of Lateral Flow Immunoassay by Magnetic Enrichment Using Multifunctional Nanocomposite Probes

Abstract: For lateral flow immunoassay (LFIA), it is an important challenge to enhance the detection sensitivity to the same level as polymerase chain reaction or enzyme-linked immunosorbent assay to make LFIA pervasive in the field of on-site environmental analysis. We recently demonstrated that the LFIA sensitivity is dramatically enhanced by using Pt-nanoparticle−latex nanocomposite beads (Pt-P2VPs) as probes for the detection of the influenza A (H1N1) antigen compared with using conventional Au colloids as probes. H… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 56 publications
0
11
0
Order By: Relevance
“…(A, ii, a) TEM image, (b) HAADF-STEM image, and (c–f) EDS elemental mapping images of Pt–P2VP@SPION. Reprinted (adapted) with permission from ref . Copyright 2021 American Chemical Society.…”
Section: Sensitivity Enhancementmentioning
confidence: 99%
See 2 more Smart Citations
“…(A, ii, a) TEM image, (b) HAADF-STEM image, and (c–f) EDS elemental mapping images of Pt–P2VP@SPION. Reprinted (adapted) with permission from ref . Copyright 2021 American Chemical Society.…”
Section: Sensitivity Enhancementmentioning
confidence: 99%
“…The former has been applied by Ren et al, 73 who have used antibody-functionalized magnetic particles in order to concentrate valosin containing protein up to 10-fold, yielding a 4000-times greater sensitivity than the conventional LFA. 73 Similarly, Son Le et al 74 have used superparamagnetic iron oxide nanoparticles (SPIONs) that provide a magnetic enrichment factor (φ) = 40, for the detection of C-reactive protein. This enables a 26-fold lower LoD (0.08 ng mL −1 ) compared to the conventional AuNPbased LFA (Figure 4A).…”
Section: Sample Preconcentrationmentioning
confidence: 99%
See 1 more Smart Citation
“…Spacing between fibers is large enough to propel the self-flow of the liquid, in high contrast with classical column chromatography (Figure ). On the basis of liquid self-transport, lateral flow strips and paper-based microfluidics for sensitive protein, DNA, , and RNA detection have been fabricated, which shows great potential in resource-poor areas. Moreover, paper chromatography has been used to separate organics and inorganic metal ions , since Martin used two-dimensional paper chromatography to complete the qualitative analysis of proteins. It might be promising in self-driven protein separation.…”
Section: Introductionmentioning
confidence: 99%
“…Various techniques (fluorescence, optic, electrochemical) are available for IgG detection and enhanced their sensitivity by applying surface modification and nanoparticle conjugation (gold, magnetic, quantum dots, etc. ). ,, An optic-based approach, surface plasmon resonance, offers many advantages such as real-time monitoring, low sample consumption, and reduced assay time . Analytical characterization of the FcγRIa as an alternative ligand molecule for site-directed IgG1 capture was performed in the current study.…”
Section: Introductionmentioning
confidence: 99%