2021
DOI: 10.1016/j.csite.2021.101444
|View full text |Cite
|
Sign up to set email alerts
|

Energy, exergy, economic (3E) analysis, optimization and comparison of different ORC based CHP systems for waste heat recovery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(8 citation statements)
references
References 42 publications
0
7
0
Order By: Relevance
“…The selection of working fluid is a critical factor in enhancing the recovery efficiency of ORC and STORC. [38][39][40] In this study, eight organic fluids are used in ORC and STORC, including hexane, cyclohexane, benzene, toluene, cyclopentane, R123, R600, and R601. In ORC and STORC, the appropriate organic fluid is used based on the performance of organic fluid.…”
Section: Results Of Waste Energy Recovery Technologiesmentioning
confidence: 99%
See 1 more Smart Citation
“…The selection of working fluid is a critical factor in enhancing the recovery efficiency of ORC and STORC. [38][39][40] In this study, eight organic fluids are used in ORC and STORC, including hexane, cyclohexane, benzene, toluene, cyclopentane, R123, R600, and R601. In ORC and STORC, the appropriate organic fluid is used based on the performance of organic fluid.…”
Section: Results Of Waste Energy Recovery Technologiesmentioning
confidence: 99%
“…Table A5 and A6 in the appendix show the parameters of ORC and STORC used in hot rolling and sintering, respectively, [36,39,41] and net power generation efficiency and energy efficiency belong to ORC and STORC systems. It is hard to compare the two technologies due to their varied waste heat recovery methods.…”
Section: Results Of Waste Energy Recovery Technologiesmentioning
confidence: 99%
“…The influence of the gap thickness, the pipe pitch in the first layer, the outer diameter of the pipe, the number of layers, and the diameter of the central core on the Nusselt number and pressure drop have been studied. The greater thickness of the dividing strip led to an increase in the volume of the flow channel on the side of the housing but a smaller number of Nusselts and a Energies 2023, 16, 4930 3 of 36 decrease in pressure drop per unit length; an increase in the pipe pitch led to a decrease in the number of Nusselts and pressure drop per unit length of the pipe; and an increase in the outer diameter of the pipe led to an increase in the number of Nusselts and pressure drop per unit length in the pipes. The number of layers had a positive effect on the Nusselt number and the pressure drop per unit length of the pipe, while the larger diameter of the central core led to higher Nusselt numbers and pressure drops.…”
Section: Literature Review On the Issue 21 Design Solutions Of Heat E...mentioning
confidence: 99%
“…The total power output and the efficiency of the proposed ICE-ORC system can be estimated by the following equations [32,33]:…”
Section: Overall Proposed Ice-orc Systemmentioning
confidence: 99%