2008
DOI: 10.1016/j.colsurfb.2008.02.003
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical behavior and voltammetric determination of norfloxacin at glassy carbon electrode modified with multi walled carbon nanotubes/Nafion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

5
44
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 90 publications
(49 citation statements)
references
References 28 publications
5
44
0
Order By: Relevance
“…This finding was in agreement with those reported for the oxidation of fluoroquinolones, such as norfloxacin. 16 The effects of the scan rate on the peak currents and the peak potentials of ENRO and CIPRO at the modified GCE were investigated in a 0.1 mol L -1 PBS using LSV in the presence of 100.0 μmol L -1 ENRO and 100.0 μmol L -1 CIPRO. The results showed that the anodic peak currents of both compounds increased linearly with the square root of the scan rate, while the ENRO and CIPRO overlap also increased.…”
Section: Effect Of Variables On the Peak Potentials And Peak Currentsmentioning
confidence: 99%
“…This finding was in agreement with those reported for the oxidation of fluoroquinolones, such as norfloxacin. 16 The effects of the scan rate on the peak currents and the peak potentials of ENRO and CIPRO at the modified GCE were investigated in a 0.1 mol L -1 PBS using LSV in the presence of 100.0 μmol L -1 ENRO and 100.0 μmol L -1 CIPRO. The results showed that the anodic peak currents of both compounds increased linearly with the square root of the scan rate, while the ENRO and CIPRO overlap also increased.…”
Section: Effect Of Variables On the Peak Potentials And Peak Currentsmentioning
confidence: 99%
“…Adsorption has been proved to be an effective way to deal with such kind of contaminants in water. Various materials, such as carbon nanotubes [16], clay minerals, and activated carbon [15], have been used as adsorbents to remove NFX.…”
mentioning
confidence: 99%
“…A simple and rapid electrochemical method was developed for the determination of trace-level norfloxacin, based on the excellent properties of multi-walled carbon nanotubes (MWCNTs) [72]. The MWCNTs/Nafion film-coated glassy carbon electrode was constructed and the electrochemical behavior of norfloxacin at the electrode was investigated in detail.…”
Section: Electrochemistry Of Fluoroquino-lones At Modified Electrodesmentioning
confidence: 99%