Electrocautery Induced Damage of Total Knee Implants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 16 publications
0
4
0
Order By: Relevance
“…ImageJ software (NIH) was used to measure and analyze electrocautery‐induced metal debris. Using previously developed techniques, 12,13 10 electron micrographs at the same magnification (x2.00k) per alloy were converted for size analysis (Figure 2) with a minimum debris diameter of 0.25 μm. Overlapping particles were removed using ImageJ analysis parameters or manually.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…ImageJ software (NIH) was used to measure and analyze electrocautery‐induced metal debris. Using previously developed techniques, 12,13 10 electron micrographs at the same magnification (x2.00k) per alloy were converted for size analysis (Figure 2) with a minimum debris diameter of 0.25 μm. Overlapping particles were removed using ImageJ analysis parameters or manually.…”
Section: Methodsmentioning
confidence: 99%
“…However, while the damage observed in this study is now thought to arise primarily from electrocautery effect, this study did show 51 to 69 components, or 74%, showing this form of damage. In a recent study of surgeon awareness of potential damage from electrocautery, 12 a survey showed that about 78% of surgeons when asked if they perform electrocautery on patients after the final components are implanted said they use electrocautery while only 38% stated that they use electrocautery during revision surgery while the implants are still placed. Also, when asked if a surgeon knew that electrocautery could induce damage, the result was that 49% said they were not aware.…”
Section: Introductionmentioning
confidence: 99%
“…Miller et al [10] investigated the extent to which the electrocautery used during surgery damages the artificial heads and the effect of this damage on the UHMWPE inserts. Their measurements used a scanning electron microscope to detect pitting and minor surface damage and a profilometer to detect surface irregularities.…”
Section: Introductionmentioning
confidence: 99%
“…They concluded that damage to the artificial head, as well as head-induced abnormalities in the vault, can be well detected using this method. However, it is questionable whether these abnormalities can cause clinical complications [10].…”
Section: Introductionmentioning
confidence: 99%