2018
DOI: 10.1088/1741-2552/aace89
|View full text |Cite
|
Sign up to set email alerts
|

Electric field measurement of two commercial active/sham coils for transcranial magnetic stimulation

Abstract: Different commercial shams induce different E-field strengths and distributions in the brain, which should be considered in interpreting outcomes of sham stimulation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
28
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 47 publications
(31 citation statements)
references
References 17 publications
2
28
0
Order By: Relevance
“…Sham NMMS was performed using a sham coil inserted in the same magnetic stimulator (Magstim AFC Coil), inducing a very shallow magnetic field. This weak magnetic field replicates the sensation of rNMMS without deep activation and with the production of similar acoustic sensations and with mechanical skin perceptions as rNMMS 40 .…”
Section: Methodssupporting
confidence: 67%
“…Sham NMMS was performed using a sham coil inserted in the same magnetic stimulator (Magstim AFC Coil), inducing a very shallow magnetic field. This weak magnetic field replicates the sensation of rNMMS without deep activation and with the production of similar acoustic sensations and with mechanical skin perceptions as rNMMS 40 .…”
Section: Methodssupporting
confidence: 67%
“…Forty sessions of treatment were administered five times a week (Monday to Friday) for 8 weeks using a MagStim Rapid stimulator (total stimuli = 64,000) (MagStim Company Ltd). In the sham group, all treatment procedures were the same as those in the 20 Hz group except for a false coil (P/N: 3950-00, Magstim Co.), which is different from the MagVenture CoolB65 Active/Placebo coil (P/N: 9016E0501; MagVenture A/S) in the intensity and distribution of the E-field in the subject's head 29 . The false coil was placed in the same position as the active treatment.…”
Section: Neuronavigated Rtms Treatmentmentioning
confidence: 99%
“…Sham stimulation was performed with the sham AirFilm Coil, keeping everything else the same. The sham coil produced clicking sounds and slight sensory stimulation while producing nearly no electric field at the center ( 31 ). To assess for blinding, after the last stimulation session, subjects completed the Stanford Expectation of Treatment Scale.…”
Section: Methodsmentioning
confidence: 99%