Efficacy of out of hospital defibrillation by ambulance technicians using automated external defibrillators. The Heartstart Scotland Project
Search citation statements
Order By: Relevance
Paper Sections
Select...
50
4
2
2
Citation Types
1
14
0
1
Year Published
Range
1993
19932017
2017Publication Types
Select...
51
3
2
Relationship
2
54
Authors
Journals
Cited by 56 publications
(16 citation statements)
References 13 publications
1
14
0
1
Order By: Relevance
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…The overall rate of survival to hospital discharge of 14.9% for patients with witnessed cardiac arrest and a primary rhythm of ventricular fibrillation is higher than the national figure3 4 and is similar to values from other well established programmes 10…”
Section: Discussion
supporting
confidence: 72%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…The overall rate of survival to hospital discharge of 14.9% for patients with witnessed cardiac arrest and a primary rhythm of ventricular fibrillation is higher than the national figure3 4 and is similar to values from other well established programmes 10…”
Section: Discussion
supporting
confidence: 72%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…In our study, 34% of patients in the test group did not receive defibrillation. The ambulances were equipped with automated defibrillators, which have been shown to administer shocks in 90-94% of patients in ventricular fibrillation 12. Therefore, the reason for not defibrillating in most cases was probably the presence of asystole or pulseless electrical activity (electromechanical dissociation) rather than inappropriate management.…”
Section: Discussion
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…Experience to date (detailed below) has consistently demonstrated excellent sensitivity for the detection of VF, as well as specificity for the detection of rhythms not requiring shock therapy (7)(8)(9)(10)(11). Sensitivity for VF detection ranges from 96% to 100%, and specificity for non-VF rhythms is near 100% in various cardiac arrest situations (9)(10)(11)(12). On rare occasions, low-amplitude, fine VF was not detected by the AED.…”
Section: Aed Technology
mentioning
confidence: 92%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…The overall rate of survival to hospital discharge of 14.9% for patients with witnessed cardiac arrest and a primary rhythm of ventricular fibrillation is higher than the national figure3 4 and is similar to values from other well established programmes 10…”
Section: Discussion
supporting
confidence: 72%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…In our study, 34% of patients in the test group did not receive defibrillation. The ambulances were equipped with automated defibrillators, which have been shown to administer shocks in 90-94% of patients in ventricular fibrillation 12. Therefore, the reason for not defibrillating in most cases was probably the presence of asystole or pulseless electrical activity (electromechanical dissociation) rather than inappropriate management.…”
Section: Discussion
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…Experience to date (detailed below) has consistently demonstrated excellent sensitivity for the detection of VF, as well as specificity for the detection of rhythms not requiring shock therapy (7)(8)(9)(10)(11). Sensitivity for VF detection ranges from 96% to 100%, and specificity for non-VF rhythms is near 100% in various cardiac arrest situations (9)(10)(11)(12). On rare occasions, low-amplitude, fine VF was not detected by the AED.…”
Section: Aed Technology
mentioning
confidence: 92%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…The overall rate of survival to hospital discharge of 14.9% for patients with witnessed cardiac arrest and a primary rhythm of ventricular fibrillation is higher than the national figure3 4 and is similar to values from other well established programmes 10…”
Section: Discussion
supporting
confidence: 72%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…In our study, 34% of patients in the test group did not receive defibrillation. The ambulances were equipped with automated defibrillators, which have been shown to administer shocks in 90-94% of patients in ventricular fibrillation 12. Therefore, the reason for not defibrillating in most cases was probably the presence of asystole or pulseless electrical activity (electromechanical dissociation) rather than inappropriate management.…”
Section: Discussion
mentioning
confidence: 99%
Abstract
Smart CitationsHow this paper cites the one you are viewing
“…Experience to date (detailed below) has consistently demonstrated excellent sensitivity for the detection of VF, as well as specificity for the detection of rhythms not requiring shock therapy (7)(8)(9)(10)(11). Sensitivity for VF detection ranges from 96% to 100%, and specificity for non-VF rhythms is near 100% in various cardiac arrest situations (9)(10)(11)(12). On rare occasions, low-amplitude, fine VF was not detected by the AED.…”
Section: Aed Technology
mentioning
confidence: 92%