2020
DOI: 10.3390/ma13225254
|View full text |Cite
|
Sign up to set email alerts
|

Effects of the Chemical Treatment on the Physical-Chemical and Electrochemical Properties of the Commercial Nafion™ NR212 Membrane

Abstract: Polymer Electrolyte Fuel Cells (PEFCs) are one of the most promising power generation systems. The main component of a PEFC is the proton exchange membrane (PEM), object of intense research to improve the efficiency of the cell. The most commonly and commercially successful used PEMs are Nafion™ perfluorosulfonic acid (PFSA) membranes, taken as a reference for the development of innovative and alternative membranes. Usually, these membranes undergo different pre-treatments to enhance their characteristics. Wit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 25 publications
0
11
0
Order By: Relevance
“…[62] Aboki et al, Bayer et al, and Hink et al recorded higher swellings in water of approximately 28%, 16%, and 17%. On the other hand, Passalacqua et al [63][64][65][66] recorded a low swelling of approximately 4% for water-saturated Nafion 212 membranes. The inconsistency in literature might result from different membrane pretreatments, measurement methods, and experimental conditions.…”
Section: Concentration Profile Of 2-propanol In Nafion 212mentioning
confidence: 97%
“…[62] Aboki et al, Bayer et al, and Hink et al recorded higher swellings in water of approximately 28%, 16%, and 17%. On the other hand, Passalacqua et al [63][64][65][66] recorded a low swelling of approximately 4% for water-saturated Nafion 212 membranes. The inconsistency in literature might result from different membrane pretreatments, measurement methods, and experimental conditions.…”
Section: Concentration Profile Of 2-propanol In Nafion 212mentioning
confidence: 97%
“…Then, the membranes were boiled successively in 3% hydrogen peroxide solution, distilled water, 1.0 M sulfuric acid solution, and distilled water for 1 h each as a swelling pretreatment. The purpose of the pretreatment is to enhance the connection between the hydrophilic channels and to provide protons as counterions to the sulfonate groups [15,16].…”
Section: Membrane Pretreatmentmentioning
confidence: 99%
“…A modification of hot press conditions and a decrease in the thickness of Nafion® membrane (NR-211, 25 μm) did not improve the peeling-off of Nafion® membrane from IrO 2 electrode. Whereas numbers of Nafion® membranes coated electrodes have been reported, [52][53][54][55][56][57][58][59][60][61][62][63] the reports of OER at the Nafion® membrane coated electrode are limited. [44,63] These references did not discuss the durability of the hot pressed Nafion® film on the electrodes.…”
Section: Attempt To Suppress Anodic Chloride Evolution Reaction (Cer)mentioning
confidence: 99%