2021
DOI: 10.1055/s-0040-1721908
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Different Amine Activators on the Monomer Conversion, Biaxial Flexural Strength, and Color Stability of Experimental Provisional Dental Restorations

Abstract: Objective The aim was to assess the effect of different amine activators including N, N-dimethyl-p-toluidine (DMPT) or Na-N-tolyglycine glycidyl methacrylate (NTGGMA) on chemical-activated monomer conversion, biaxial flexural strength (BFS), and color stability of composites for provisional dental restorations. Materials and Methods Two formulations of composites containing either DMPT (D-temp) or NTGGMA (N-temp) were prepared. The degree of monomer conversion was assessed. The BFS of the materials was tested … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 40 publications
1
5
0
Order By: Relevance
“…All the specimen and jig dimensions are considered in the BFS equation used. 13,19 For this study, the specimens' diameter was 10 mm, according to Padunglappisit et al 14 The thickness was set for 2 mm to simulate the occlusal clearance in crown preparation and to avoid premature fracture during mechanical aging. An Isomet precision diamond saw was used for cutting of the CAD-CAM-milled cylinders to minimize the waste of the material and for standardization.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…All the specimen and jig dimensions are considered in the BFS equation used. 13,19 For this study, the specimens' diameter was 10 mm, according to Padunglappisit et al 14 The thickness was set for 2 mm to simulate the occlusal clearance in crown preparation and to avoid premature fracture during mechanical aging. An Isomet precision diamond saw was used for cutting of the CAD-CAM-milled cylinders to minimize the waste of the material and for standardization.…”
Section: Discussionmentioning
confidence: 99%
“…All the specimen and jig dimensions are considered in the BFS equation used 13,19 . For this study, the specimens’ diameter was 10 mm, according to Padunglappisit et al 14 . The thickness was set for 2 mm to simulate the occlusal clearance in crown preparation and to avoid premature fracture during mechanical aging.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The measurement was conducted following the protocol reported in the previous study [ 48 ]. Briefly, disc specimens were prepared and immersed in deionized water at a controlled temperature of 37 °C for 7 days.…”
Section: Methodsmentioning
confidence: 99%
“…The speed of elongation was set at 1 mm/min. The experimental procedure was performed according to standards in the case of a piston-ring configuration by ASTM F394-78 [33] and other previous works [34]. The calculations proposed by Kirsten and Woolley [35] allowed Glandus [36] to reach the formula Equation ( 3).…”
Section: Mechanical Resistancementioning
confidence: 99%