2016
DOI: 10.1016/j.matchemphys.2016.03.023
|View full text |Cite
|
Sign up to set email alerts
|

Effect of pulse plating parameters on the structure and properties of electrodeposited Ni Mo films

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
12
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 35 publications
(14 citation statements)
references
References 46 publications
2
12
0
Order By: Relevance
“…The relation between potential and current is an important characteristic in electrochemistry, describing electrocatalytic activities, electrodeposition processes, , corrosion, , redox processes, capacitances, cell performances, , and so forth. To characterize these electrochemical properties, one typically applies a time-dependent potential and measures the current or vice versa.…”
Section: Introductionmentioning
confidence: 99%
“…The relation between potential and current is an important characteristic in electrochemistry, describing electrocatalytic activities, electrodeposition processes, , corrosion, , redox processes, capacitances, cell performances, , and so forth. To characterize these electrochemical properties, one typically applies a time-dependent potential and measures the current or vice versa.…”
Section: Introductionmentioning
confidence: 99%
“…Ni-based alloys are widely used cathodes for the electrolysis of alkaline waters due to the relatively high catalytic activity of Ni, and the synergism in the catalytic behavior of various components in the metal alloy. Alloys such as NiCo [35][36][37][38][39][40][41], NiFe [42][43][44][45][46], NiMo [43,[47][48][49][50][51][52][53][54][55][56][57][58][59], NiW [47,60,61], NiCu [62,63], NiAl [6,[64][65][66][67][68], NiZn [69][70][71][72][73], NiMoFe [56,[74][75][76][77] were used by means of different methods. Materials based on nickel and molybdenum attract ever growing attention because of their activity for HER and sufficient corrosion resistance in...…”
Section: Chemical Problems 2018 No 3 (16)mentioning
confidence: 99%
“…Finally the wires were connected to the pulse power. According to previous work [11,12,14,15], the parameters were set as shown in table 2 below. After electroplating, the tube was taken out and washed by ultrasonic cleaning, then annealed at 500 °C for 2 h, 4 h and 6 h respectively.…”
Section: Sample Pretreatmentmentioning
confidence: 99%