2019
DOI: 10.3390/inventions4030038
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Hybrid Power Station Installation in the Operation of Insular Power Systems

Abstract: Greece has a large number of islands that are isolated from the main interconnected Greek power system; however, a majority of them are to be interconnected in the mainland grid over the next decade. A large number of these islands present a significant amount of wind and solar potential. The nature of load demand and renewable production is stochastic; thus, the operation of such isolated power systems can be improved significantly by the installation of a large-scale energy storage system. The role of storag… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
1

Year Published

2020
2020
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 20 publications
0
4
0
1
Order By: Relevance
“…Three hybrid stations of different size in Samos were shown to increase the capacity factor of the island, with a penetration of 39% [42]. The annual simulation of energy production in the island of Ikaria was reported with a Wind/PHS increasing the RES penetration by 50% [43].…”
Section: Pumped Hydro Storage Hybridsmentioning
confidence: 99%
“…Three hybrid stations of different size in Samos were shown to increase the capacity factor of the island, with a penetration of 39% [42]. The annual simulation of energy production in the island of Ikaria was reported with a Wind/PHS increasing the RES penetration by 50% [43].…”
Section: Pumped Hydro Storage Hybridsmentioning
confidence: 99%
“…It represents a power system (with a rated frequency of 50 Hz) dominated by thermal and wind generation within a frequency control area. This is a typical case of many island electric systems, in which the excursions of the frequency (either under normal conditions, due to intermittent injection of power from non-conventional renewable energy sources, or in contingency situations, due to the sudden loss of generation units or consumption centers) are very pronounced compared to a continental system [38,39]. In the example illustrated in Figure 3, the thermal generation is represented by the linearized model of the prime mover of a steam turbine and its speed governor [35].…”
Section: Case Studymentioning
confidence: 99%
“…Esta situación es de enorme preocupación en sistemas eléctricos débiles y aislados, en los cuales la cuota de participación de la generación renovable en el mix energético es equiparable o supera a la generación convencional, tal como lo muestran estudios publicados en [9][10][11]. No obstante, muchas de las soluciones que se proponen en la literatura para mitigar los inconvenientes antes expuestos están basados justamente en la utilización de más convertidores electrónicos, normalmente, asociados a sistemas de almacenamiento energético (baterías, volantes de inercia, supercondensadores, entre otros).…”
Section: Figura 1 Convertidor Electrónico De Potencia Conectado a La Redunclassified