Effect of EEG electrode number on epileptic source localization in pediatric patients

Abstract: Objective To investigate the relationship between EEG source localization and the number of scalp EEG recording channels. Methods 128 EEG channel recordings of 5 pediatric patients with medically intractable partial epilepsy were used to perform source localization of interictal spikes. The results were compared with surgical resection and intracranial recordings. Various electrode configurations were tested and a series of computer simulations based on a realistic head boundary element model were also perfo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

10
76
0
2

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 126 publications
(91 citation statements)
references
References 63 publications
10
76
0
2
Order By: Relevance
“…Additionally, it would be interesting to study the effect of electrode number on solution precision (within the new framework). While there are several studies suggesting that increasing the number of electrodes helps improve source localization results significantly (Brodbeck et al, 2011; Lantz et al, 2003; Michel et al, 2004a; Sohrabpour et al, 2015; Srinivasan et al, 1998), determining the relation between the number of electrodes and solution precision awaits future experimentation. Whether plateauing effects will be observed as suggested by Sohrabpour et al (Sohrabpour et al, 2015) or not, can only be determined after further investigations (specifically in clinical data).…”
Section: Discussionmentioning
confidence: 99%
“…Additionally, it would be interesting to study the effect of electrode number on solution precision (within the new framework). While there are several studies suggesting that increasing the number of electrodes helps improve source localization results significantly (Brodbeck et al, 2011; Lantz et al, 2003; Michel et al, 2004a; Sohrabpour et al, 2015; Srinivasan et al, 1998), determining the relation between the number of electrodes and solution precision awaits future experimentation. Whether plateauing effects will be observed as suggested by Sohrabpour et al (Sohrabpour et al, 2015) or not, can only be determined after further investigations (specifically in clinical data).…”
Section: Discussionmentioning
confidence: 99%
“…Localization accuracy increases in a non-linear fashion with the number of electrodes, and estimates indicate that probably no less than 500 electrodes would be needed for an accurate sampling of the surface potential distribution [31, 32]. But it has also been pointed out recently that the absolute improvement in accuracy decreases with the number of electrodes [33]. Bayesian approaches, have been reviewed recently [34], allow to compare several models and indicate that spatial localization precision in the milimeter range can be achieved reliably.…”
Section: Introductionmentioning
confidence: 99%
“…In this issue of Clinical Neurophysiology, Sohrabpour et al evaluate source localization accuracy of 4 electrode configurations in a case series of 5 pediatric patients with high density EEG and individual MRIs using electrocorticography recordings and surgical resections with good outcome to measure accuracy (Sohrabpour et al, 2014). These authors conclude that increasing electrode number decreases localization error, though this improvement plateaus.…”
mentioning
confidence: 99%