2018
DOI: 10.1590/0104-1428.004616
|View full text |Cite
|
Sign up to set email alerts
|

Effect of disinfection techniques on physical-mechanical properties of a microwave-activated acrylic resin

Abstract: ObstractThe effects of disinfection by microwave irradiation and immersion in peracetic acid on the physical-mechanical properties of a microwave-activated acrylic resin were evaluated. Specimens of acrylic resin were divided into a control group (specimens not disinfected) and 2 test groups subjected to one disinfection method: microwave irradiation at 850 W for 1 minute or immersion in 50 mL of 0.2% peracetic acid for 5 minutes. Specimens were submitted to Knoop hardness, flexural strength, flexural modulus,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 26 publications
0
3
0
Order By: Relevance
“…9 Numerous protocols have been used for microwave denture sterilization including the use of different power and time, but different studies have indicated a need for reducing the time of microwave exposure in order to reduce the side effects over a long period of use. 2,9 So in the present study, the microwave oven was used at 850W for 1min because this energy and time are capable of sterilizing the denture from Candida albicans contamination. 6,13 The findings showed that the disinfection of specimens in the microwave at 850W for 1min had a non-significant effect on the tensile strength.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…9 Numerous protocols have been used for microwave denture sterilization including the use of different power and time, but different studies have indicated a need for reducing the time of microwave exposure in order to reduce the side effects over a long period of use. 2,9 So in the present study, the microwave oven was used at 850W for 1min because this energy and time are capable of sterilizing the denture from Candida albicans contamination. 6,13 The findings showed that the disinfection of specimens in the microwave at 850W for 1min had a non-significant effect on the tensile strength.…”
Section: Discussionmentioning
confidence: 99%
“…This is in agreement with Fortes et al, 6 who found the protocol of microwaving at 850 W for 1min had no effect on the flexural strength of the acrylic. 2 We also used 650W for 6min, as 650W has been reported to inactivate Staphylococcus aureus, Pseudomonas aeruginosa, and spore forms of Bacillus subtilis and it is an effective method for acrylic resin disinfection. 25 In the current study, this protocol minimized the strength in comparison to other groups, in agreement with Konchada et al, 7 who reported a decrease in flexural strength values among three different acrylic resins.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation