2020
DOI: 10.1002/rcs.2158
|View full text |Cite
|
Sign up to set email alerts
|

easyEndo robotic endoscopy system: Development and usability test in a randomized controlled trial with novices and physicians

Abstract: Background Some difficulties are common when using endoscopes. Steering is not intuitive, the endoscope weight is a physical burden to physicians and communication problems often occur between operators. Method To overcome these, we developed a robotic endoscopy system and conducted a usability test to compare conventional and robotic manipulation. Nine novices and eighteen physicians participated with the physicians being divided into intermediate and expert groups. The participants performed endoscope insert… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 13 publications
(10 citation statements)
references
References 24 publications
0
10
0
Order By: Relevance
“…The novices completed the tasks more quickly and with a lower workload when using robotic manipulation, whereas the experts showed the opposite trend. The learning rate in all groups was greater for robotic manipulation (21.02% on average) than for conventional manipulation (13.75%) [32,33] .…”
Section: Easyendo Robotic Endoscopy System (Easyuretero)mentioning
confidence: 85%
See 1 more Smart Citation
“…The novices completed the tasks more quickly and with a lower workload when using robotic manipulation, whereas the experts showed the opposite trend. The learning rate in all groups was greater for robotic manipulation (21.02% on average) than for conventional manipulation (13.75%) [32,33] .…”
Section: Easyendo Robotic Endoscopy System (Easyuretero)mentioning
confidence: 85%
“…This robotic catheter system was modified and equipped with a fiber endoscope and a customized ureteral catheter to perform ureteroscopy with the commercial master device Omega 3 (Force Dimension, Switzerland), although the existing drawbacks of inappropriate control mode and inadequate working range partially contributed to the termination and eventual failure of this project [22,26,27] . Kwon et al [32,33] 2022 easyEndo robotic endoscopy system (EasyUretero) Phantom None…”
Section: Sensai-magellan Systemmentioning
confidence: 99%
“…provides an actuation of the colonoscope's bending and rotation DoFs and the EE's translation and rotation DoFs via a single custom controller. The endoscope handle with the surrounding actuation unit is attached to two passive positioning arms [22].…”
Section: A Attachable Actuation Units For Flexible Endoscopesmentioning
confidence: 99%
“…If the mapping among them is not aligned or the control direction is not compatible, the inconsistency between visual perception and movement control makes it difficult to accurately manipulate the tool 2–7 . In the case of the flexible endoscope, the compatibility between the control direction of the control handle and the image is poor (Figure 1), resulting in poor operability 8–10 …”
Section: Introductionmentioning
confidence: 99%