IEEE Power and Energy Society Conference and Exposition in Africa: Intelligent Grid Integration of Renewable Energy Resources ( 2012
DOI: 10.1109/powerafrica.2012.6498618
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic line rating systems for wind power integration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 20 publications
0
8
0
Order By: Relevance
“…14 Wind power injected to system for case 30-bus system Fig. 15 Solar power injected to system for case 30-bus system inadequacy of lines capacity. According to the results, in comparison with STR technology the proposed method can provide 90.72-99.6% reduction in cost, 93.5-99.52% reduction in curtailment of wind power, 98.5-99.86% reduction in curtailment of solar power, and 98.87-99.13% reduction in LS in IEEE 24-and 30-bus test systems, respectively.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…14 Wind power injected to system for case 30-bus system Fig. 15 Solar power injected to system for case 30-bus system inadequacy of lines capacity. According to the results, in comparison with STR technology the proposed method can provide 90.72-99.6% reduction in cost, 93.5-99.52% reduction in curtailment of wind power, 98.5-99.86% reduction in curtailment of solar power, and 98.87-99.13% reduction in LS in IEEE 24-and 30-bus test systems, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…Many investigations have been conducted on the impact of DTR on power networks. Among them, many studies are focusing on the DTR impact on the penetration of RESs, especially wind turbines/farms [10][11][12][13][14][15][16]. In [10], it has been shown that DTR consideration has positive effects on the penetration level of wind turbines.…”
Section: Introductionmentioning
confidence: 99%
“…Besides, there is also a specific section in [1] devoted to the relationship between DLR and wind power integration supported by a practical evidence area dedicated to this specific topic. A brief version of the study in [1] was also presented as an overview analysis on the same topic in another venue by the same group of authors in [4]. A field data based detailed overview of the considerations regarding the selection of proper DLR technique was presented in [5] with very detailed technical details on the different industrial technologies gathered from real implementations.…”
Section: Literature Reviewmentioning
confidence: 99%
“…DLR estimates the line ampacity in real time with monitored weather conditions taking account of the wind cooling effect [15]. It can be obtained using a variety of methods: conductor sag and tension monitoring, vibration mode analysis, conductor temperature and local weather data [4], [15].…”
Section: Proposed Calculation Of Dlrmentioning
confidence: 99%
“…It can be obtained using a variety of methods: conductor sag and tension monitoring, vibration mode analysis, conductor temperature and local weather data [4], [15]. Many trials have been carried out on using online measurement and communicate with the DSO or the devices to set the realtime line capacity [16]- [19].…”
Section: Proposed Calculation Of Dlrmentioning
confidence: 99%