2022
DOI: 10.1016/j.jmrt.2022.08.139
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic compression behavior of ultra-high performance concrete with hybrid polyoxymethylene fiber and steel fiber

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 26 publications
(9 citation statements)
references
References 52 publications
0
2
0
Order By: Relevance
“…The SHPB experimental apparatus includes a striker and incident, transmission and absorption bars, as specifically shown in Figure 7. To avoid the influence of surface roughness at the contact interface on the RuAAC's impact performance, the contact surfaces of the specimens were polished before the experiment to ensure that the surface roughness was less than 0.02 mm [45,46]. To eliminate the high-frequency influence of stress waves and prolong the rising time of the incident wave, a brass pulse shaper with a diameter of 20 mm and a thickness of 2 mm was used [45,47,48].…”
Section: Split-hopkinson Pressure Bar Testmentioning
confidence: 99%
See 2 more Smart Citations
“…The SHPB experimental apparatus includes a striker and incident, transmission and absorption bars, as specifically shown in Figure 7. To avoid the influence of surface roughness at the contact interface on the RuAAC's impact performance, the contact surfaces of the specimens were polished before the experiment to ensure that the surface roughness was less than 0.02 mm [45,46]. To eliminate the high-frequency influence of stress waves and prolong the rising time of the incident wave, a brass pulse shaper with a diameter of 20 mm and a thickness of 2 mm was used [45,47,48].…”
Section: Split-hopkinson Pressure Bar Testmentioning
confidence: 99%
“…To avoid the influence of surface roughness at the contact interface on the RuAAC's impact performance, the contact surfaces of the specimens were polished before the experiment to ensure that the surface roughness was less than 0.02 mm [45,46]. To eliminate the high-frequency influence of stress waves and prolong the rising time of the incident wave, a brass pulse shaper with a diameter of 20 mm and a thickness of 2 mm was used [45,47,48]. Strain gauges were attached to the incident and transmission bars to measure dynamic strains, which were collected at a frequency of 1 MHz using a dynamic strain acquisition instrument.…”
Section: Split-hopkinson Pressure Bar Testmentioning
confidence: 99%
See 1 more Smart Citation
“…UHPC is known for its extremely high compressive strength (≥120 MPa), durability, and high toughness [4][5][6]. However, it also has limitations, in terms of deformation and crack control [7,8].…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, the utilization of aggregates in UHPC, such as natural river sand, has resulted in increased mining costs due to the diminishing availability of natural resources. Coupled with the high cost of steel fibres, this considerably escalates the production expenses of UHPC [7][8][9][10][11][12]. Consequently, the carbon footprint of UHPC is 2.52 times that of ordinary concrete, and the production cost is 8.3 times higher than that of ordinary concrete [1,13,14].…”
Section: Introductionmentioning
confidence: 99%