2007
DOI: 10.1667/rr0302.1
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetry for a Study of Low-Dose Radiation Cataracts among Chernobyl Clean-up Workers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
16
0
2

Year Published

2007
2007
2019
2019

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 49 publications
(20 citation statements)
references
References 29 publications
(45 reference statements)
2
16
0
2
Order By: Relevance
“…However, from calculations and experimental simulations made by Osanov et al (1993b) as well as by clinical manifestations on the skin it should be concluded that beta doses of unprotected skin and even eye lenses (Osanov et al 1993b;Nossovsky and Krjuchkov 1996;Chumak et al 2007) had exceeded respective wholebody gamma doses, sometimes significantly. Time dependence of the beta dose contribution (beta/gamma dose ratio) has a pronounced maximum at a time about 1 y after the accident ) because several very short-lived radionuclides ( 140 Ba/La, 132 Te, and 131 I) are gamma emitters, while the main high-energy beta emitters ( 144 Ce/Pr and 106 Ru/Rh), which were significant for remote beta irradiation of the lens and skin, have a half-life of ϳ1 y.…”
Section: Monitoring Of Doses Other Than the External Whole-body Gammamentioning
confidence: 98%
“…However, from calculations and experimental simulations made by Osanov et al (1993b) as well as by clinical manifestations on the skin it should be concluded that beta doses of unprotected skin and even eye lenses (Osanov et al 1993b;Nossovsky and Krjuchkov 1996;Chumak et al 2007) had exceeded respective wholebody gamma doses, sometimes significantly. Time dependence of the beta dose contribution (beta/gamma dose ratio) has a pronounced maximum at a time about 1 y after the accident ) because several very short-lived radionuclides ( 140 Ba/La, 132 Te, and 131 I) are gamma emitters, while the main high-energy beta emitters ( 144 Ce/Pr and 106 Ru/Rh), which were significant for remote beta irradiation of the lens and skin, have a half-life of ϳ1 y.…”
Section: Monitoring Of Doses Other Than the External Whole-body Gammamentioning
confidence: 98%
“…The details of the dosimetry aspects are provided in the companion paper (23). In brief, several groups of workers active on-site from April 26, 1986-December 31, 1987 were deemed suitable for inclusion in the study based on the initially available dosimetry information.…”
Section: Dosimetry and Study Populationmentioning
confidence: 99%
“…As described in ref. (23), bias corrections and uncertainty estimates based on available information were then applied, and the lens ␤-particle doses were estimated with their own uncertainties. The distribution of individual doses (␥ rays and ␤ particles combined) are plotted in Fig.…”
Section: Dosimetry and Study Populationmentioning
confidence: 99%
“…37 The highest tissue-averaged dose observed in the present study was 176 mGy (Table 3). Eye model fjl had the highest percentage of volume receiving in excess of doses 300 mGy, and no lens volume received a dose over 400 mGy ( Table 2).…”
Section: Discussionmentioning
confidence: 52%